4.4.1
Resistance of magnetic tape against chemical influences
Table 2: Resistance of magnetic tape against chemical influences
Show no or little effect in constant contact after 2-5 years:
Formic acid
Cotton seed oil
Formaldehyde 40%
Show weak to moderate effects in constant contact after approximately 1 year:
Acetone
Acetylene
Ammonia
Kerosene
Have strong effects when contacting permanently after 1-5 months:
Benzene
Lacquer solvent
Trichloroethylene

5 Installation and First Start-Up

CAUTION
Please read the operating manual carefully before using the device! Strictly observe the Instal-
lation instructions! In case of damage caused by failure to observe this operating manual, the
warranty expires.
ELGO is not liable for any secondary damage and for damage to persons, property or assets.
The operator is obliged to take appropriate safety measures. The first start-up may only be
performed by staff that has been trained and authorized by the operator.
5.1

Operating Area

WARNING!
Do not use the device in explosive or corrosive environments!
The device must not be installed close to sources of strong inductive
or capacitive interference or strong electrostatic fields!
Glycerol 93°C
N-hexane
Iso-octane
Petrol/gasoline
Steam
Acetic acid 20%
Nitric acid 70%
Nitric acid, red, vitriolic
Nitrobenzene
Linseed oil
Lactic acid
Petroleum
Acetic acid 30%
Acetic acid (pure)8
Isopropyl ether
Turpentine
Carbon tetrachloride
Hydrochloric acid 37%,
93°C
- 10 -
Technical Data
Soy beans oil
Oleic acid
Sea water
Stearic acid 70°C,
anhydrous
Toluene
Tetrahydrofuran
Xylene