*Note: STRINGI have the following format
Number of bytes
Means
1
Number of string
3
Language set
1
EPATH
2
Character Set
1
Length
Length
State Descriptions
Attribute 5
Adapted from document [CIP] "
Bit
Called
0
Owned
1
Reserved, shall be 0 Reserved, shall be 0
2
Configured.
3
Reserved, shall be 0 Reserved, shall be 0
Extended Device
4-7
Status
Minor
Recoverable
8
Fault
Minor
9
Unrecoverable
Fault.
Major
Recoverable
10
Fault.
Major
11
Unrecoverable Fault
12-15 Reserved, shall be 0 Reserved, shall be 0
0x01
'eng' (0x65 0x6E 0x67)
0xDA
0x04 0x00
16 (0x10)
Value
'User Name String'
(0x55 0x73 0x65 0x72 0x20 0x4E 0x61 0x6D 0x20 0x53 0x74 0x72 0x69 0x6E
0x67)
THE CIP NETWORKS LIBRARY
Definition
TRUE indicates the device (or an object within the device) has an owner.
Within the Master/Slave paradigm the setting of this bit means that the
Predefined Master/Slave Connection Set has been allocated to a master.
Outside the Master/Slave paradigm the meaning of this bit is TBD.
 unused
TRUE indicates the application of the device has been configured to do
something different than the "out–of–box" default. This shall not include
configuration of the communications.
0
Self-Testing or Unknown
1
Firmware Update in Progress
2
At least one faulted I/O connection
3
No I/O connections established
4
Non-Volatile Configuration bad
5
Major Fault – either bit 10 or bit 11 is true (1)
6
At least one I/O connection in run mode
7
At least one I/O connection established, all in idle mode
8
Reserved, shall be 0
9-15
Vendor/Product specific  unused
TRUE indicates the device detected a problem with itself, which is thought to
be recoverable.
The problem does not cause the device to go into one of the faulted states.
TRUE indicates the device detected a problem with itself, which is thought to
be unrecoverable. The problem does not cause the device to go into one of
the faulted states.
TRUE indicates the device detected a problem with itself, which caused the
device to go into the "Major Recoverable Fault" state.
TRUE indicates the device detected a problem with itself, which caused the
device to go into the "Major Unrecoverable Fault" state.