Technical Specifications - Siemens CP 5613 A3 Operating Instructions Manual

Pg/pc - profibus
Hide thumbs Also See for CP 5613 A3:
Table of Contents

Advertisement

Technical specifications

Technical specifications CP 5613 A3 / CP 5614 A3
Connection to PROFIBUS
Connection to PG/PC
Electrical specifications of the PCI plug-in connector
Operating voltage
Current consumption
Effective power loss
Permitted ambient conditions
Operating conditions
CP 5613 A3 / CP 5614 A3
Operating Instructions, 10/2012, C79000-G8976-C277-01
Amount
For CP 5613 A3
For CP 5614 A3
Transmission speeds
Design
Properties
Rated voltage
Permitted range
Properties
Typical
For CP 5613 A3
For CP 5614 A3
Typical
For CP 5613 A3
For CP 5614 A3
Temperature
(EN 60068-2-1+2)
Temperature change max.
Rel. humidity
(EN 60068-2-78)
Rapid temperature change
(EN 60068-2-14)
1
2
9.6 kbps, 19.2 kbps, 45.45 kbps,
93.75 kbps, 187.5 kbps, 500 kbps,
1.5 Mbps, 3 Mbps, 6 Mbps, 12 Mbps
9-pin D-sub female connector with screw
locking mechanism
RS-485 (ungrounded within the SELV
limits)
Grounded cable shield
Floating interface signals
PCI, 33 MHz / 66 MHz, 32 bit
signal voltage: 5 VDC or 3.3 VDC
V 2.2 plug and play
3.3 VDC and 12 VDC
3.0 to 3.6 VDC
11.0 to 13.0 VDC
Safety extra low voltage (SELV) to EN
60950
150 mA at 3.3 V and 250 mA at 12 V
180 mA at 3.3V and 280 mA at 12 V
3.5
3.9 W
+5...+50°C
≤10 K/h
≤ 85% at 30°C no condensation
+5...+50°C, 5 cycles
5
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp 5614 a3

Table of Contents