Resetting Nv Data To Defaults - 3Com LANPLEX 6000 User Manual

Administration console
Hide thumbs Also See for LANPLEX 6000:
Table of Contents

Advertisement

Resetting NV
Data to Defaults
Top-Level Menu
system
display
ethernet
save
softwareUpdate
fddi
restore
baseline
tokenring
examine
serialPort
bridge
reset
password
ip
name
snmp
time
analyzer
screenHeight
script
consoleLock
logout
panelLock
ctlKeys
nvData
reboot
At times you may not want to restore the system NV data. Instead, you may
want to reset the values to the factory defaults so that you can start
configuring the system from the original settings.
CAUTION: Resetting the NV data means that all NV memory is set back to
the factory defaults. Before proceeding, ensure that you want to reset your
NV data.
To reset all the NV data on the system to the original default values:
1 From the top level of the Administration Console, enter:
system nvData reset
You see the following prompt:
Resetting NV data may leave the system in an inconsistent
state and therefore a reboot is necessary after each reset.
Do you with to continue (n,y) [y]:
2 Confirm that you want to reset NV data by entering
you enter
(yes) the system will reboot. If you enter
y
returned to the previous menu.
3 Reboot the system.

Resetting NV Data to Defaults

(yes) at the prompt. If
y
(no), you are
n
7-7