μIO-Stick User Manual
5 Fast LIN BSL Support
Figure 11
BSL Tool - Configuration Button
Figure 12
displays the Configuration dialog. Here, the user selects the desired target device, BSL protocol, baud
rate, and the behavior of the integrated VS charge pump.
Figure 12
BSL Tool - Configuration
Target Device - select the target device from the pull-down list.
Protocol - select the desired BSL protocol and BSL interface:
-
Normal LIN - BSL communication uses real LIN frames, Master-Request frames, and Slave-Response
frames. In order to distinguish these BSL LIN frames from real LIN frames, the checksum is inverted.
Communication is via the target device integrated LIN transceiver.
-
Fast-LIN - UART like BSL communication using the device integrated LIN transceiver. This is the default
protocol for new, unprogrammed devices.
-
UART - full-duplex UART communication over UART1 of the target device.
Baud Rate - selects the communication baud rate.
Pin VS - selects the usage/behavior of the VS pin (Pin 6):
-
Off - the µIO-Stick integrated charge pump is switched off, VS must be supplied by the target system,
see also
Figure 6
-
On - the µIO-Stick integrated charge pump is switched on, and remains on. Please see also
page 9.
-
Off during Reset - the µIO-Stick integrated charge pump is switched off during the reset phase before
the connection attempt is started, see also
Application Note
on page 10.
Figure 4
on page 9.