Choose one of the following options. Default = Data Formatter On, Not Required,
Keep Prefix/Suffix.

Data Format Non-Match Error Tone

When a bar code is encountered that doesn't match your required data format, the
8680i normally generates an error tone. However, you may want to continue scan-
ning bar codes without hearing the error tone. If you scan the Data Format Non-
Match Error Tone Off bar code, data that doesn't conform to your data format is
90
a data format is not found for that symbol, the prefixes and suffixes are
transmitted.
Data Format Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted. Any data that does not match your data format
requirements generates an error tone and the data in that bar code is not
transmitted. If you wish to process this type of bar code without generating an
error tone, see
Data Format Non-Match Error
Data Format Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is
found for a particular symbol, those prefixes and suffixes are not transmitted.
Any data that does not match your data format requirements generates an error
tone. If you wish to process this type of bar code without generating an error
tone, see
Data Format Non-Match Error
* Data Formatter On,
Not Required,
Keep Prefix/Suffix
Data Format Required,
Keep Prefix/Suffix
Tone.
Tone.
Data Format Required,
Data Formatter On,
Not Required,
Drop Prefix/Suffix
Drop Prefix/Suffix