Download Print this page

GE LRXS4 Installation Manual page 3

Lrx series, new construction frame, led luminaire

Advertisement

Bars
A
5
Option A: Mount fixture by attaching hanger bars
to T-Grid ceiling (BH3 SKU 94890).
Option B: Mount fixture with ½" EMT conduit.
Note: Supplied by 3rd party.
LRXS-Series Mounting
AC line and dimming wires
7
Connect conduit end with input leads to existing junction box and make proper connections. Connect the black,
white, and green/yellow wires of the input leads to the black, white and green wires using twist-on wire connectors
and close junction box.
Optional dimmer: When connecting with dimming controller, wires must be run through another separate
knockout hole. Connect the violet (dimming +) and gray (dimming -) wires to the violet and gray wires of the fixture.
NOTE: Please cover dimming leads with wire nuts if you won't connect with dimming leads.
Lumens Setting Switch
NOTE: For 1000/650lm product, default output lumen is
1000lm. Push switch up to activate 650lm.
Conduit
B
Input and dimming
wires from J-box
Adjust height and
tighten wing nut
6
Adjust fixture height to be flush with ceiling and
tighten both mounting bracket wing nuts.
Wiring Diagram
L
N
Ground
0-10 Volt Dimming (Optional)
Gray
LED
Driver
Violet
Maximum Quantity Of Fixtures That Can Be
Connected With One Dimmer
No.
Dimmer Type
1
QSN - 4T16 - S
2
GRX TV1 with Grafik Eye QS Main Unit
3
NTFTV/NFTV/DVTV with PP - 120
4
TVM2 Module
5
TVI - LMF -2S
3
Black
White
LRX
Fixture
Green/Yellow
To 0-10V
0-10V –
Dimmer
0-10V +
Maximum
Fixture
Quantity
80
520
40
80
35

Advertisement

loading

This manual is also suitable for:

Lrxs8Lrxs6