MAIN MENU
SUB MENU
Receive
Set DMX Address
User Mode
Edit A
User Mode
Edit B
Edit C
Status
Fixture ID
ProtocolSet
Function
KlingNet
Net Switch
Fan. Set
LCD. Set
Dim Curve
Temp. C/F
Init. Effect
Disp. Set
Pixel
DFSE
Time. Info
Information
Temp. Info
Error Info
Model. Info
Software Version
S Y S T E M M E N U
Supports Software Version: ≥ V1.08
Features are subject to change without any prior written notice.
OPTIONS / VALUES
001 ~ XXX
Standard, Basic, Extend, User A, User B, User C
Max. Chan
:
Chase Fade
Remote Add
NoDMX Mode
Pan Invert
Tilt Invert
Pan Degree
Feedback
Move. Spd
Stand By
ServicePIN
RDM PID
NOTE: ServicePIN must be entered in order to set fixture IP Address and Universe
Unit IP Addr
Universe
ArtNet, SACN
Enable / Disable
ON / OFF
Head Fan
Backlight
FlipDisplay
Key Lock
Disp Flash
Standard, Stage, TV, Architectur, Theatre
Fahrenheit/Celsius
PAN =XXX
Chan. Value
Slave Set
Auto. Pro
Standard, Flip
ON / OFF
Current
Total Time
Last Clear
Timer PIN
Clear Last
Head Temp.
Error Record 1 ~ Error Record 10
ChorusLine16
1U01 - 5U01
(Default Settings in BOLD)
ON/OFF
Hold / Auto / Blackout
ON / OFF
ON / OFF
630/540
ON/OFF
Speed 1 ~ 4
OFF, 01M~99M, 15M
PIN=XXX
XXXXX
XXX.XXX.XXX.XXX.
000-255
Auto, High, Low
02~60m 05m
ON / OFF
ON / OFF
ON / OFF
PAN...
Slave 1, Slave 2, Slave 3
Alone, Master
XXXX (Hours)
XXXX (Hours)
XXXX (Hours)
PIN= 066
ON / OFF
XXX F° / C°
≥V1.08
14
DESCRIPTION
DMX Address Setting
Set DMX Channel Mode
Edit User Defined
Channel Assignments
Set Fixture Address Via DMX Control
Function If NO DMX Detected
Pan Reverse Movement
Tilt Reverse Movement
Pan Degree Select
Movement Feedback
Movement Mode Select
Stand By Mode
Service PIN 050
RDM PID Code
Enter Fixture's IP Address
Enter Universe Number
Set Network Protocol
Enable KlingNet Protocol
Activate NET OUT Port.
Fan Speed Set
LCD Backlight Shut Off Time
Flip/Reverse LCD Display 180º
Control Front Panel Buttons Key Lock
Display flashes when NO DMX
Set Dimmer Curve Mode
Temperature Switch Between F˚/ C˚
Initial Effect Position
Value of each Channel Displayed
Set Slave Mode Preset
Set Auto Program Mode
Set Pixel Flip Mode
Restore Factory Settings
Fixture Run Time From Power ON
Fixture Total Run Time
Clear Fixture Last Run Time
Enter PIN to Access Clear Last. Menu
Reset Fixture Last Run Time
Temperature in Fixture Head
Display 10 Recent Error Messages
Display Model Name
Software Versions