GE SVi 1000 Masonelian Quick Start Manual page 66

Table of Contents

Advertisement

Housing
Magnetic Field Influence
Accuracy
Hysteresis and Deadband
Repeatability
Conformity
Start-Up Drift
Long Term Drift
Position Travel Limits
Flow Characteristics
Applied in addition to the control valve's
inherent characteristic.
Tight Shut Off
66 | =GE Oil & Gas
Table 6: Environmental Specifications (Continued)
Table 7: Operational Specifications
Tropicalized with positive pressure
Negligible at 100 A/m 50/60 Hz (EN61000-4-8)
CE MARK
The SVi1000 conforms to the requirements of the ATEX
94/9/EC and EMC 2014/30/EU directives.
+/- 1.0% (typical or less) Full Span
+/- 0.3% Full Span
+/- 0.3% Full Span
+/- 0.5% Full Span
Less than 0.02% in first hour
Less than 0.003% per month
Rotary: 18 - 140°
Reciprocating: 0.25" - 2.5" (6 mm - 64 mm)
Note: Above 2.5" (64 mm) consult factory for
mounting instructions.
Linear
Equal Percentage (of 50:1 or 30:1)
Camflex
Quick Opening (inverse of 50:1 equal percent-
age)
User Configurable
0 -20% of input
© 2016 General Electric Company. All rights reserved
.