Sanyo 12KHS71 Submittal Data
Sanyo 12KHS71 Submittal Data

Sanyo 12KHS71 Submittal Data

Split system indoor/outdoor wall mounted heat pump
Hide thumbs Also See for 12KHS71:

Advertisement

Split System Submittal Data
System: 12KHS71
Wall Mounted Heat Pump
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
Fuse Size, Max.

Compressor

No. used
R.L. Amps - L.R.
Crankcase Heater

Outdoor Unit

Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
No. Motors
(High)
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
(in.)
Tube Size

Indoor Unit

Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
No. Motors
(W)
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
(A)
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
(in.)
Drain Connection Size
Indoor/Outdoor: KHS1271/CH1271

General Data (at 115V)

115/1/60
(A)
(A)
DC Rotary Inverter
(A)
9.8/10.6-20
(W)
Propeller
15-3/4-1
Direct - 3
(RPM)
8-750
(W)
(A)
Aluminum Fin & Copper Pipe
Corrugated Plate - Inner Rif ed
2-18.1
5/16"
Cross Flow
D3-11/6 L24-31/32-1
3 & Auto
(RPM, High)
4-1250
14.8-1
294/259/212
0.346
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Rif ed
2-19.5
9/32"
(in.)
23/32"
Approval:
Date:
Construction:
Unit #:
Drawing #:
20
20

Refrigerant

Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max (ft.)
20
Lift Difference, Max (ft.)
Line Size
Line Size

Dimensions

Indoor Unit
30-1
1059
Outdoor Unit
0.6

Weight

Net
Shipping
3.95
Shipping Volume

Performance Data @ ARI Standard Conditions (230/208V)

Cooling

Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
36
Amps
Power Inputs
Outdoor Sound Rating
Total Capacity
2.02
HSPF

Electric Expansion Valve

(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
11-7/32 x 32-15/32 x 7-7/16
(Crated)
13-25/32 x 35-7/16 x 10-1/32
(Uncrated)
21-9/16 x 28-11/32 x 10-7/16
(Crated)
23-5/8 x 33-11/16 x 14-1/4
Indoor
(lbs.)
19.8
(lbs.)
24.3
Indoor
(cu.ft.)
2.82
(BTU/H)
11,900 (3,000-11,900)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
-/10.9 (2.5-10.9)
(W)
-/1,090 (250-1,090)
(dB-A)
(BTU/H) 14,300 (3,000-14,300)
R410A
2.43
Flare
65
23
1/4"
3/8"
H x W x D
Outdoor
77.2
83.8
Outdoor
6.36
9,100
2,800
17
4.26
47
9.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 12KHS71 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sanyo 12KHS71

  • Page 1 Split System Submittal Data System: 12KHS71 Indoor/Outdoor: KHS1271/CH1271 Wall Mounted Heat Pump Job Name: Location: Engineer: Submitted to: Submitted by: Reference: General Data (at 115V) Power V/PH/Hz Circuit Ampacity Fuse Size, Max. Compressor No. used R.L. Amps - L.R. Crankcase Heater...
  • Page 2 Temperature Control Timer Night Setback (Horizontal) Air Louver (Vertical) Power Failure Automatic Restart Dimensional Data for 09KHS71 / 12KHS71 Heating/Cooling Automatic Changeover Indoor unit : KHS0971 / KHS1271 Self-Diagnosis Quiet Operation Ion Generator Air Clean Apatite Filter Dimensional Data for 09KHS71 / 12KHS71...

This manual is also suitable for:

Khs1271Ch1271

Table of Contents