Installation notes
Installing several SmartLine
elements
The gaps between the individual Smart-
Line elements are sealed with a silicone
sealant that is heat-resistant to at least
160 °C. With flush-fit installation, the
gap between the SmartLine element(s)
and the worktop must also be sealed
with a silicone sealant that is heat-res-
istant to at least 160 °C.
After installation, the SmartLine ele-
ments must be easily accessible from
below, so that the bottom half of the
casing can be removed for mainten-
ance. If the SmartLine elements are not
accessible from below, the sealant must
be removed so that they can be re-
moved.

Minimum plinth height

The downdraft extractor fan is installed
in the plinth below the cabinet floor. The
minimum plinth height must be
100 mm.

Worktop depth

The downdraft extractor can be in-
stalled with the connector for the air
duct on either the right or the left side.
Minimum worktop depth for
– right connector 600 mm
– left connector 665 mm
28
THE EASIEST WAY TO SELF-IMPORT APPLIANCES DIRECT FROM EUROPE.
Housing unit back panel
The extraction ducting is laid behind the
housing unit back panel. The back
panel must be removable for mainten-
ance purposes.
Grease trap
The downdraft extractor must be in-
stalled in such a way that the grease
trap is freely accessible and can be re-
moved for cleaning.