Thermofuse; Freezer Fan Motor; Refrigerator Fan Motor; Electronic Control - Whirlpool WRX-17TM Service Manual

Silver color, electronic no frost refrigerator dual fan, maestro project, high range smile design
Table of Contents

Advertisement

4.2.3. Thermofuse

Turned on in series connection with the heater defrost, the thermofuse protects the product and does not allow
that defrost heater be turned on continuously in case of failure of the defrost sensor. In case of failures in the
defrost system when the heater is continuously working, it will open at the range of 72 °C to 77 ° C.

4.3. Freezer Fan Motor

The Fan motor is a (V dc) motor and is fixed to the rear cover of the evaporator through a rubber flexible holder
(freezer), that protects from occasional vibrations, and consequently noise.

4.4. Refrigerator Fan Motor

The Refrigerator fan motor is also fed by direct voltage (V dc), therefore, located inside the wind flow, fixed
to a plastic housing by flexible rubber holder, which avoids occasional vibrations and consequently noise. it is
responsible for the forced air circulation inside the refrigerator compartment.

4.5. Electronic Control

The complete operation of this product is done by the electronic control, which executes the functions according
to the necessities, turning the components on or off through received/managed signals.
Inside its box, the electronic control is divided in 2 parts, a main board and a line filter.
Main board
Technical Characterístics:
Rated voltage: 24 Vdc
Operating range : 20,4 Vdc - 27,6 Vdc
Current max (a): 0,18 a
Potency max: 4,3 W
Speed rated: 3000 rpm
Technical Characterístics:
Rated voltage: 24 Vdc
Operating range : 20,4 Vdc - 27,6 Vdc
Current max (a): 0,1 a
Potency max: 2,9 W
Speed rated: 2900 to 3500 rpm
Line filter
CN1 – Compressor and power coard
CN2 – Load components and lamps
CN3 – Temperature sensors
CN4 – Interface board
Note: More details, check the wiring diagram