Water And Ice Dispensers - Whirlpool WRF954CIHV Use And Care Manual

Door-within-door french door refrigerator
Hide thumbs Also See for WRF954CIHV:
Table of Contents

Advertisement

Available languages

Available languages

Water and Ice Dispensers

IMPORTANT:
Allow 3 hours for the refrigerator to cool down and chill water.
Allow 24 hours to produce the first batch of ice. Discard the
first three batches of ice produced.
The dispensing system will not operate if the left-hand
refrigerator door is open.
A. Water dispenser paddle
B. Ice dispenser paddle
Flush the Water System
Air in the water dispensing system can cause the water dispenser
to drip. After connecting the refrigerator to a water source or
replacing the water filter, flush the water system.
Flushing the water dispensing system forces air from the water
line and filter and prepares the water filter for use. Additional
flushing may be required in some households.
NOTE: As air is cleared from the system, water may spurt out of
the dispenser.
1. Using a sturdy container, depress and hold the water
dispenser paddle for 5 seconds.
2. Release the dispenser paddle for 5 seconds. Repeat steps
1 and 2 until water begins to flow.
3. Once water begins to flow, continue depressing and releasing
the dispenser pad (5 seconds on, 5 seconds off) until a total
of 3 gal. (12 L) has been dispensed.
26
20-Jun-2017 10:09:25 EDT | RELEASED
Dispensing Calibration
Household water pressure may affect the accuracy of the
Measured Fill feature. So, for optimum performance of your
water dispenser, you must first calibrate Measured Fill.
IMPORTANT:
Flush the water system before calibrating Measured Fill.
For best results, calibration should be performed when water
is not being used in the house.
1. Place a sturdy measuring cup (1 cup [237 mL] size) on the
dispenser tray centered in front of the ice/water dispenser
paddle.
NOTE: Depending on your model, a measuring cup may be
provided.
A
B
Ensure that you do not have any Measured Fill preset
selected.
2. To enter Calibration Mode, go to Tools > More Modes >
Calibration. Calibration can also be done the first time the
refrigerator is powered on.
3. Press and hold the water dispenser paddle, as needed, to
dispense water to the 1 cup fill line in the measuring cup.
NOTE: If overfilling or spilling occurs, discard the water and
restart the calibration process.
4. When 1 cup of water has been correctly dispensed into the
measuring cup, touch OK to confirm the calibration.
In some European factories the letter "W" of the part code mentioned herein will be automatically
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")
A. Water dispenser paddle
B. Ice dispenser paddle
C. Measuring cup (1 cup)
A
B
C