ELECTRICAL WIRING
WARNING
Electrical Shock Hazard
• An electrical ground is required on this
appliance.
• Do not connect to the electrical supply
until the appliance is permanently
grounded.
• Turn off power to the junction box before
making the electrical connections.
• Connect the appliance to a grounded,
metallic, permanent wiring system.
Failure to follow these instructions could
result in death or serious injury.
1.
Insert the end of the flexible conduit through
the cabinet opening to the junction box
inlet.
2.
Disconnect the power going to the junc-
tion box.
3.
Open the junction box cover and connect
the flexible conduit to the U.L.-listed con-
duit connector.
4.
Connect the ends of the black wires to-
gether with twist-on connectors (see the
illustration below).
5.
Connect the ends of the red wires together
with twist-on connectors.
cable from
power supply
junction box
red wires
white wire
white & bare
grounding
appliance wires
factory crimped
cable from
Crimped Grounding Conductors
To White (Neutral) Wire
black wires
U.L.-listed
conduit
connector
oven
If local codes DO permit connecting the cabi-
net-grounding conductor to a neutral junction
box wire, perform steps 6 and 7.
If local codes DO NOT permit connecting the
cabinet-grounding conductor to a neutral junc-
tion box wire, or if you are connecting the
appliance to a 4-wire electrical system, per-
form steps 8 through 11.
6.
Connect the factory-crimped bare and
white electrical wires coming from the
appliance conduit cable to the white (neu-
tral) wire inside the junction box (see the
illustration below).
7.
Replace the junction box cover.
8.
Separate the factory-crimped bare and
white electrical wires coming from the
appliance conduit cable.
9.
Connect the white appliance wire to the
white (neutral) wire inside the junction
box.
10. Connect the bare grounding wire from the
appliance to a grounded wire inside the
junction box. IMPORTANT: Do not con-
nect the bare grounding wire to the
white (neutral) wire in the junction box.
11. Replace the junction box cover.
junction box
red wires
bare
grounding
appliance wires
Separate Grounding Conductors
To White (Neutral) & Bare Wires
2-2
cable from
power supply
white wires
black wires
U.L.-listed
conduit
cable from
connector
oven