Wiring diagram of the turnstile connection to access control system (ACS) in hold mode
inp1- "PANIC"
inp2- "TO BE OPENED A" in pulse mode. When command is issued entry is activated for 5 sec.
inp3- " TO BE OPENED B" in pulse mode. When command is issued entry is activated for 5 sec.
inp4- "TO BE OPENED A". Entry is activated for the time of keeping in active state
inp5- " TO BE OPENED B". Entry is activated for the time of keeping in active state
GND- "-" of power supply (common wire)
out3 - "DETECTION OF ACCESS A"
out4 - "DETECTION OF ACCESS B"
Figure D.2 – Wiring diagram of the turnstile connection to ACS
Annex D.2
(mandatory)
Signal is generated by controller when rotor is rotating
from 64 o to 120 o in the relevant direction