22 TROUBLESHOOTING
Faults
High oil consumption
Headlight and position light are
not functioning
Turn signal, brake light, and
horn are not functional
Time is not displayed or not
correctly displayed
Battery discharged
The combination instrument
shows nothing on the display
Speedometer in combination
instrument not functioning
228
Possible cause
Engine oil level too high
Engine oil too thin (low viscos-
ity)
Fuse 6 blown
Fuse 4 or 6 blown
Fuse 2 or 7 blown
Ignition was not switched off
when vehicle was parked
Battery is not being charged
by alternator
Fuse 2 or 7 blown
Speedometer wiring harness is
damaged or plug-in connector
is oxidized
Action
Check the engine oil level. (
Change the engine oil and oil filter and
clean the oil screens.
(
Change the fuses of individual power
consumers. (
p. 187)
Change the fuses of individual power
consumers. (
p. 187)
Change the fuses of individual power
consumers. (
p. 187)
Recharge the battery.
Check the charging voltage.
Check the open-circuit current.
Change the fuses of individual power
consumers. (
p. 187)
Check the wiring harness and plug-in
connector.
p. 211)