Download Print this page

Siemens RCC-3 Installation Instructions Manual

Remote command center

Advertisement

Quick Links

Installation Instructions

Model RCC-3/-3R/-3C/-3F/-3FC/-3FR
Remote Command Center
INTRODUCTION
The Model RCC-3/-3R/-3C Remote Command
Center from Siemens Industry, Inc. is an optional
MXL/MXLV System remote keyboard panel (See
Figure 1). The RCC-3R is red and will be re-
ferred to in the remainder of this document as
the RCC-3. The RCC-3F/-3FC/-3FR Remote
Command Center, which is used for flush
mounting applications, has a 3/4 inch flange on
all four sides of the enclosure. The RCC-3FR is
red and will be referred to in the remainder of
this document as the RCC-3F.
CAUTION: When preparing the opening for the
RCC-3F/-3FC make sure it does not exceed the
Siemens Industry, Inc.
Building Technologies Division
Florham Park, NJ
P/N 315-048665-7
C le a r le n s
RCC-3C/3FC Remote Command Center
dimensions of the enclosure as shown in Figure 2,
plus the dimensions of the flange.
The panel in the RCC-3/-3C/-3F/-3FC has a multi-
line display that continuously updates information
about the system event status. If there are
multiple events (alarms, security conditions,
supervisories and/or troubles), the highest
priority event that occurred displays on the
screen. The user can view up to 8 events at a
time and can scroll through the complete list
using the Up (
next to the More Info key. For further information
H E L P /
A I DE
P R I N T /
I MP.
S PA CE /
E S PAC E
CL E A R /
E N T E R /
E F FAC E R
E N T R E R
K e y b o a rd /D is
Figure 1
Siemens Building Technologies, Ltd.
Fire Safety & Security Products
2 Kenview Boulevard
Brampton, Ontario
L6T 5E4 Canada
) and Down (
) keys located
p la y p a n e l

Advertisement

loading

Summary of Contents for Siemens RCC-3

  • Page 1: Installation Instructions

    Center from Siemens Industry, Inc. is an optional MXL/MXLV System remote keyboard panel (See The panel in the RCC-3/-3C/-3F/-3FC has a multi- Figure 1). The RCC-3R is red and will be re- line display that continuously updates information ferred to in the remainder of this document as about the system event status.
  • Page 2: Installation

    It is also used to perform specific menu-driven operations, as well as programming and maintenance The RCC-3/-3C/3F/-3FC comes with the key- functions. board/display panel installed in the enclosure and a clear lens installed in the door, as shown in Separate UP and DOWN keys located next to the Figure 1.
  • Page 3 Chassis GND (Earth GND). controls are easily accessible. 5. Remove the connector plugs from J12. 2. Set the Network Address for the RCC-3 Attach the field wiring to the connector plugs, using the three ten-position rotary switches making sure that position 1 on J12 is for...
  • Page 4 70 according to NEC 760. 2. Use a maximum of 80 ohms per pair of wires for the network connections. 7. The RCC-3/-3C/-3F/-3FC MUST have an earth ground connected to the chassis. Wire 3. Use shielded twisted pair for network connections.
  • Page 5 70 according to NEC 760. 2. Use a maximum of 80 ohms per pair of wires for the network connections. 9. The RCC-3/-3C/-3F/-3FC MUST have an earth ground connected to the chassis. Wire shield or 3. Use shielded twisted pair for network connections.
  • Page 6 MMB-3 Notes: 1. Use a minimum wire gauge of 22 AWG. 7. The RCC-3/-3C/-3F/-3FC MUST have an earth ground connected to the chassis. Wire shield or 2. Use a maximum of 80 ohms per pair of wires for the network connections.
  • Page 7: Electrical Ratings

    7. If needed, J11 is the connector for a parallel CCU/M and RDM-1 Wiring printer and J10 is the connector for a serial to MKB-5/-6 or RCC-3 printer. The serial connection can be RCC-3 CCU/M OR RDM-1 supervised; the parallel connection is PORT C supervised by default.
  • Page 8 Siemens Industry, Inc. Siemens Building Technologies, Ltd. Building Technologies Division Fire Safety & Security Products Florham Park, NJ 2 Kenview Boulevard Brampton, Ontario P/N 315-048665-7 L6T 5E4 Canada...

This manual is also suitable for: