Storage Controller Module; Removing The Storage Controller Module - Dell PowerEdge FD332 Owner's Manual

Hide thumbs Also See for PowerEdge FD332:
Table of Contents

Advertisement

When aligned correctly, the drive rails are flush with the surface of the hard drive/SSD.
3
Install the screws to secure the drive to the drive rails.
Next steps
1
Open the drive drawer.
2
Install the drive assembly in the drive drawer.
3
Close the drive drawer.
Related links
Removing a hard drive/SSD from the drive rails
Installing a hard drive/SSD assembly
Opening the drive drawer
Closing the drive drawer

Storage controller module

You system supports one storage controller module (SCM), which is available in four options:
FD33xS—storage controller module with single PERC
FD33xD—storage controller module with dual PERC
FD33xS—storage controller module with single HBA
FD33xD—storage controller module with dual HBA
NOTE:
The default mode for all storage controller modules is HBA mode. To enable RAID mode for a PERC controller, you must
upgrade to RAID mode licensing. For more information on RAID mode licensing, see the PowerEdge FX2s CMC User's Guide at
dell.com/esmmanuals. For information on how to import RAID mode license, see the Dell PowerEdge FX2/FX2s CMC
Help .
For more information on the storage controller modules, and removing and installing the SCM components, see the Dell PowerEdge RAID
Controller (PERC) 9 User's Guide at dell.com/storagecontrollermanuals and Dell Host Bus Adaptor User's Guide at https://
www.dell.com/support/home/us/en/19/products/server_int/server_data_center_infrastructure .

Removing the storage controller module

Prerequisites
CAUTION:
Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
NOTE:
This is a field replaceable unit (FRU). Removal and installation procedures must be performed only by Dell certified
service technicians.
NOTE:
You must remove the storage controller module (SCM) to replace a faulty module.
1
Ensure that you read the
2
Follow the procedure listed in
3
Keep the T15 Torx screwdriver ready for the storage controller module cable screws.
4
Keep the #2 Phillips screwdriver ready for the screws securing the storage controller module to the module holder.
Steps
1
Open the drive drawer until the storage controller module is accessible.
2
Loosen the screws securing the module cable to the SCM.
32
Installing and removing storage sled components
Safety
instructions.
Before working inside your
system.
Online

Advertisement

Table of Contents
loading