Sony TRINITRON KD-30XS955 Service Manual page 9

Trinitron series da-4 chassis
Hide thumbs Also See for TRINITRON KD-30XS955:
Table of Contents

Advertisement

Self-Diagnostic Screen Display
For errors with symptoms such as "power sometimes shuts off" or "screen sometimes goes out" that cannot be confi rmed, it is possible to bring up past
occurrences of failure on the screen for confi rmation.
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander sequentially, in rapid succession, as shown below:
DISPLAY
Handling of Self-Diagnostic Screen Display
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen during repairs. When you
have completed the repairs, clear the result display to "0".
Unless the result display is cleared to "0", the self-diagnostic function will not be able to detect subsequent faults after completion of the repairs.
Clearing the Result Display
To clear the result display to "0", press buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as shown below:
NOTE: This will also reset all user functions (including auto programming and picture settings)
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.
Self-Diagnostic Circuit
STBY-LED
48
44
45
43
KD-30XS955/34XBR960/34XS955/36XS955
Downloaded from
www.Manualslib.com
Channel 5
Sound volume -
MZ
IC2300
MAIN MICRO
STR
CLKO
29
STBY-LED
DATO
OCP
30
OVP
LOW B ERR
AC RLY
69
Q6527
Q6530
ENABLE ON
LATCH
Q6532
LATCH
AZ
IC504
SV REF
5V
O
I
UNREG 7V
O
manuals search engine
Power ON.
SELF DIAGNOSIS
2: +B OCP
3: +B OVP
4: VSTOP
5: AKB
6: LOWB
7: H-STOP
101: WDT
BY
IC2801
Y/C JUNGLE
AKB
58
CRT
SCL
26
35
VDY-
VPROT
R5104
25
SDA
34
HPROT
R5125
RY6501
Q5018
P_SW(-)
1
2
INVERT
4
3
DZ
1K-PROT2
+B OVP
UNREG 11V
D6537
D6505
HV PROT
D5007
KD-30XS955/34XBR960/34XS955/36XS955
0
0
Numeral "0"
0
means that no fault was detected.
1
Numeral "1"
0
means a fault was detected one
0
time only.
24
R5105
BY
DZ
2
IC5007
14
H. PROT
MONITOR
IC6505
+B OVP
PH6501
IN RUSH
+B
1
OVER CURRENT
4
1
3
2
R5013
+B
DZ
Q5004
+ B COP
D5005
DETECT
+B OCP
5V
Q6522
FOLLOWER
2
3
+B
9

Hide quick links: