Installing The Indoor Unit - Mitsubishi Electric PFFY-P20VKM-E Installation Manual

City multi series conditioner for building application indoor unit
Hide thumbs Also See for PFFY-P20VKM-E:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

3. Installing the indoor unit

Fig. 3-1
Fig. 3-3
1)
131
Fig. 3-2
Fig. 3-4
674
Fig. 3-5
Fig. 3-6
700
131
288
78
23
599
Fig. 3-7
(mm)
3.1. Indoor unit mounting bracket installation
• Install the bracket firmly to the wall structure (stud, etc.). (Fig. 3-1)
• Use a level to install the mounting bracket horizontally.
• Install the indoor unit 150 mm or below from the floor.
Indoor unit mounting bracket
A
Note:
To prevent the indoor unit mounting bracket from vibrating slightly, be sure
to fasten the bracket at the holes indicated by
bracket at the holes indicated by
3.2. Indoor unit preparation
Press the 2 positions indicated by the arrows
1
(Fig. 3-3)
Open the front grille and remove the 2 screws.
2
Open the horizontal vane for the upper air outlet, push the top of the front panel
3
in 3 locations, and then pull the top of the grille away from the indoor unit.
Screws
B
Lift up the front grille to remove it. (Fig. 3-4)
4
3.3. Indoor unit installation (Fig. 3-5)
• Hook the top of the indoor unit on the indoor unit mounting bracket.
• Use the included wood screws and washer, and fasten the indoor unit at 2 loca-
tions ( ) each at the top and the middle of the unit.
Note:
Install the indoor unit securely to the wall, making sure that there is no gap
between the unit and the wall.
3.4. Making holes in the wall and floor
3.4.1. Making holes (Fig. 3-6)
1 Make ø65 mm or ø75 mm holes that are approximately 5–7 mm deep and an-
gled slightly downward outward from the room.
2 Insert the wall hole sleeves into the holes.
Wall hole
A
65 mm or 75 mm dia.
B
Indoor side
C
Wall hole cross section
D
Wall thickness
E
One scale
F
Cut with 1 extra scale length.
G
Wall hole sleeve
H
Caution:
Be sure to use the wall hole sleeves. Otherwise, the indoor/outdoor unit con-
necting wires may contact a metal object in the wall or, in the case of hollow
walls, small rodents may gnaw on the wires, resulting in a very dangerous
situation.
3.4.2. Determining hole positions
The areas where the piping can be routed are indicated with oblique lines in the
figure.
1) For rear or left-rear piping (Fig. 3-7)
(The following figure is a front view of the indoor unit installation location.)
. In addition, fasten the
if possible. (Fig. 3-2)
and open the front grille.
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents