968XTP Maximum Security Switch - Installation Instructions

General Guidelines

• Mount the magnet
assembly to the
door, mount the
switch assembly to
the frame.
Align
Edges
Step 1 - Install the Magnet
• Place the magnet
2" (51 mm)
[minimum] from
the side of the
door frame and
3/16" (4.8 mm)
from the top.
• Mark the two
mounting holes
and drill pilot
holes for #8
(4.1 mm) screws
[provided].
Frame
• Mount the
magnet on the
door using two #8
(4.1 mm) screws
with the Honeywell label surface facing down and the arrow
pointing away from the door.
Step 2 - Install the Tamper Plate
• Line up the edge of the tamper plate to the edge of the magnet.
Make sure the
arrows on the
tamper plate
are pointing
#8
toward the
(4.1 mm)
door.
Screw
• Measure the
gap distance
7/16" ±1/16"
(11.1 mm ±1.6
mm).
• Mark the
mounting holes
and drill pilot
Frame
holes for two
#6 (3.5mm)
and four #8
(4.1 mm)
screws [provided].
• Mount the tamper plate in place using two #6 (3.5 mm) screws.
For the latest U.S. warranty information, please go to: www.honeywell.com/security/hsc/resources/wa or
Please contact your local authorized Honeywell representative for product warranty information.
 2006 Honeywell International Inc. Honeywell is a registered trademark of Honeywell International Inc.
All other trademarks are the properties of their respective owners. All rights reserved. Assembled in Mexico.
Outswinging Door Instructions
Frame
Door
Area to be
Area to be
OPEN
7/16"
protected
protected
11.1 mm
Door
2" (51 mm)
Minimum
#8
(4.1 mm)
#6
Screw
(3.5 mm)
7/16"
Screw
(11.1 mm)
Door
Step 3 - Install the Switch
• Verify that the
arrow on the
switch assembly
is facing the arrow
on the magnet
3/16"
assembly.
4.8 mm
• Mount the switch
assembly to the
tamper plate
using four #8
(4.1 mm) screws
[provided].
• See
Supplemental
Information for
wiring
instructions.
3/16"
Supplemental Information
(4.8 mm)
Wiring
• The normal condition of the 968XTP is when it is reporting secure,
energized by the magnet.
• The two white tamper wires will be closed when the tamper switch
is in secure condition.
• The tamper contacts should be connected to a 24 hour circuit to
trigger an alarm any time the switch module is tampered with.
• Maximum contact ratings depend on the voltage put through the
switch. They are 250 mA at 12 V or less and 125 mA at 24 V. The
tamper circuit can handle a maximum of 1 Amp.
Black
Common
Green
Normally Closed (NC)
Red
Normally Open (NO)
White
Tamper NC
White
Tamper NC
Notes
• To minimize tamper potential, the 968XTP should be installed inside the
perimeter being protected.
• The switch assembly / magnet combination is designed to have a
nominal gap of 0.45" (11.4 mm). The system will go into alarm
condition if the gap is approximately 0.63" (16.0 mm) and greater,
or approximately 0.27" (6.9 mm) or less. To account for system
tolerances, a 7/16" ±1/16" (11.1 mm ±1.6 mm) gap has been specified
Align edges
in these instructions. The minimum make gap is 0.53" (13.5 mm).
• Approvals/listings:
EN 50131-1:2006 and EN 50131-2-6:2008 Security Grade 3
Environmental Class II; Certified by VdS.
Suitable for connection to an EN 60950 Class II
Limited Power Source in European Installations.
For any additional information, please refer to our Website,
www.honeywell.com/security/emea/hscdownload or contact:
Honeywell Security Group
Quality Assurance Dept.
Newhouse Industrial Estate
Motherwell
Lanarkshire ML1 5SB
United Kingdom
Protected under
US Patent 6,963,281.
Frame
Green
Red
Black
White
White
cULus listed
Tel: +44(0)1698 738200
Email: UK64Sales@Honeywell.com
Ê5-051-649-00F4Š
P/N 5-051-649-00F 9/11 Rev A
Door
NC
NO
COM
Tamper NC
Tamper NC

Advertisement

loading