HONEYWELL EXCEL 5000 OPEN SYSTEM

GENERAL INFORMATION

Depending on your application's hardware requirements, you
can choose between the following different Excel 12 models:
W7704A1004
230 Vac power supply; length 180 mm
five relays (incl. three normally-open relays and two
changeover relays) and four triac outputs
four binary inputs
seven analog inputs
two analog outputs (0...10 V)
one LED output
W7704B1002
230 Vac power supply; length: 180 mm
three normally-open relays and six triac outputs
four binary inputs
seven analog inputs
two analog outputs (0...10 V)
one LED output
W7704C1000
24 Vac power supply; length: 126 mm
six triac outputs
four binary inputs
seven analog inputs
two analog outputs (0...10 V)
one LED output
W7704D1008
24 Vac power supply; length: 126 mm
five relays (incl. three normally-open relays and two
changeover relays) and six triac outputs
four binary inputs
seven analog inputs
two analog outputs (0...10 V)
one LED output
W7704D1016
230 Vac power supply; length: 180 mm
five relays (incl. three normally-open relays and two
changeover relays) and six triac outputs
four binary inputs
seven analog inputs
two analog outputs (0...10 V)
one LED output
® U.S. Registered Trademark
Copyright © 2005 Honeywell Inc.
All Rights Reserved
INSTALLATION INSTRUCTIONS
W7704D1024 (for Japan, only)
100 Vac power supply; length: 180 mm
five relays (incl. three normally-open relays and two
changeover relays) and six triac outputs
four binary inputs
six analog inputs, plus AI6 (which is suitable for
reading input from LESST wall modules, only)
two analog outputs (0...10 V)
one LED output
W7704E1005 (for Japan, only)
24 Vac power supply; length: 126 mm
two relays (both normally-open) and three triac outputs
four binary inputs
two analog inputs, plus AI6 (which is suitable for
reading input from LESST wall modules, only)
one analog output (0...10 Vdc)
W7704F1003
230 Vac power supply; length 180 mm
four relays (incl. three normally-open relays and one
changeover relay) and four triac outputs
four binary inputs
two analog inputs
two analog outputs (0...10 V)
one LED output

BEFORE INSTALLATION

IMPORTANT
It is recommended that the Excel 12 be kept at room
temperature for at least 24 hours before applying
power; this is to allow the evaporation of any
condensation resulting from low shipping / storage
temperatures.
CAUTION
To avoid electrical shock or equipment damage, you
must turn off the power supply before attaching /
removing connections to/from any terminals.
Mounting
The Excel 12 is available with either short (W x L x H =
126 x 76 x 110 mm) or long (W x L x H = 180 x 76 x 110 mm)
housings (see Fig. 1) conforming to IP20/30. The mounting
procedures are similar for both sizes.
The Excel 12 is suitable for mounting on a standard rail (DIN
EN 50022-35 x 7,5) and for installation in wiring cabinets, in
fuse boxes, and on walls/ceilings.
Excel 12
W7704
EN1B-0201GE51 R0905C

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell EXCEL 12 W7704B1002

  • Page 1: General Information

    Excel 12 W7704 HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION INSTRUCTIONS GENERAL INFORMATION W7704D1024 (for Japan, only) • 100 Vac power supply; length: 180 mm • Depending on your application's hardware requirements, you five relays (incl. three normally-open relays and two...
  • Page 2: Terminal Assignment

    EXCEL 12 MODULES Wall/Ceiling Mounting/Dismounting swivel label short housing: 100 mm; long housing: 154 mm holders (optional) round hole (diameter: 4 mm) terminal protection terminal protection cover (optional) cover (optional) oval hole (4x7 mm) Fig. 3. Drilling template (view from above) The unit can be mounted on walls or ceilings in any Fig.
  • Page 3: Power Supply

    EXCEL 12 MODULES Honeywell W7704A1004 230 Vac +10/-15%; 20VA 50/60 Hz; Rel.Com. Max 6A IP30 with terminal cover X: not used 1401 Rel1 Rel2 Rel3 Rel4 Rel4 Rel4 Rel5 Rel5 Rel5 Rel123 O: out, only Power Power date code model-specific information...
  • Page 4: Wall Modules

    24 Vac sunblind +/-20% hardwired to the Excel 12, its LED can be configured (using Honeywell's LNS plug-in) to provide information about e.g. 230 Vac 120 Vac overrides or effective occupancy modes. Further, in the case of a T7560 Wall Module, its LCD can likewise be configured Fig.
  • Page 5 IV 22 AWG (Belden part number 9D220150) or plenum-rated configured as slow binary inputs using Honeywell's LNS plug- level IV 22 AWG (Belden part number 9H2201504) non- shielded, twisted-pair, solid-conductor wire.
  • Page 6: Analog Inputs

    Once the outputs have been configured using 550 mA for max. 10 sec. • cos ϕ > 0.5 Honeywell's LNS plug-in, floating actuators can be directly Hardware Limits for Excel 12 with 24 Vac Power Supply connected to them. •...
  • Page 7: Troubleshooting

    Check if switching the power OFF/ON changes the One or two L terminations are required, depending ORKS service LED's behavior. Please contact Honeywell ORKS on the given LonWorks bus layout. if this does not solve the problem. Two different L...
  • Page 8 NEC failure is recognized. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Straβe 17...

Table of Contents