IMPORTANT SERVICE NOTES (DX-361 EM ONLY)
Before returning the unit to the customer after completion of a repair or adjustment it is necessary for the following withstand voltage
test to be applied to ensure the unit is safe for the customer to use.
Setting of Withstanding Voltage Tester and set.
Set name
Set value
Withstanding Voltage Tester
Test voltage
4,240 VPEAK
3,000 VRMS
Set time
3 sees
Set current (Cutoff current)
3 mA
Unit
Power
ON
Judgment
01<: The "GOOD" lamp lights.
NG: The "NG" lamp lights and the buzzor sounds.
AC
WITHSTANDING
VOLTAGE TESTER
PROBE
CONNECT THE PROBE
TO GND TERMINAL
OF MAIN CHASSIS
WIRING OF PRIMARilY SUPPLY LEADS (DX-361 EM ONLY)
If anyone of the nylon bands shown in the Fig. 4 is removed for
some reason, be sure to replace it to the original position and
the same appearance as before.
AC
Power
Supply Cord
QACCBOI03UF08
QACCBOI03UFOO
QACCBOI03AFOO
Transformer
Figure 4
-4-