Installation Instructions

Please Note:
This product should only be installed by a qualifi ed electrician
or competent heating installer and should be in accordance with
the current edition of the IEEE wiring regulations.
Specifi cation
Thermostat Features
Power supply
Memory backup
Switching action of output relay
Switch rating of relay contact,
voltage and current
Transmitter frequency (RF only) 433.92 MHz
Transmitter range (RF only)
Rated Impulse Voltage
Dimensions (mm)
Ball Pressure Test
Temperature Range
Design Standard
Control Pollution Situation
Time accuracy
Temperature accuracy
*1: Unit must powered up for 6 days to charge cell before full back-up is available
Important note RF products: Ensure that there are no large metal objects,
such as boiler cases or other large appliances, in line of sight between the
transmitter and receiver as these will prevent communication between
thermostat and receiver.
TP7000
TP7000-RF
TP7000A
2 x AA/MN1500/LR6
alkaline batteries
Capacitor during
battery change for 1
minute
N/A
N/A
30m max.
N/A
138 wide x 88 high x 28 deep
EN 60730-2-7 (EN300220 for RF)
Degree 2
± 1 min.
TP7000-M
TP7000-M 24
TP7000-MA
230v, 50 Hz
24v, 50 Hz
Rechargable cell, 24 hrs (*1)
1 x SPDT, Type 1B
3(1) A, 10-230 volts
N/A
N/A
2.5Kv
75°C
5-30°C
±1°C
GB
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tp7000Tp7000-mTp7000-maTp7000-m 24Tp7000a