Milwaukee MC740 User Manual
Milwaukee MC740 User Manual

Milwaukee MC740 User Manual

Mc311 ec controller with mp810 1,5 l/h dosing pump
Hide thumbs Also See for MC740:

Advertisement

Mount the bracket in the wall in upright position above the water
container (which contains a solution of EC reducing acid and
water).
Place the pump in vertical position (with the tubes below) on the
wall, above and centered with the "Mounting bracket". Then go
down the pump until it is joined with the bracket.
Connect the pump to the MC311 EC controller (on the black and
white outlet). The pump will discharge 0,08 cL every 2 seconds
when active.
Place the plug and B/W outlet far away from water!
Before servicing (maintenance) on the pump (e.g. changing
tube), please disconnect the equipment.
It is suggested to dissolve 10 cL of Mono-nutrient in a 5L container of water. Depending
on the volume of your tank and the brand of your Mono-nutrient (and whether it is more
or less concentrated), this quantity can be increased later. It is better to dissolve more
than less. It is suggested to use an airstone on the bottom of your tank. The pump can
be attached directly to the container of the solution.

OPTIONAL ACCESSORIES:

M10000B
Electrode rinse solution, 20 ml sachet (25 pcs)
M10031B
1413 μS/cm calibration solution, 20 ml sachet (25 pcs)
M10032B
1382 ppm calibration solution, 20 ml sachet (25 pcs)
MA9061
1413 μS/cm calibration solution, 230 ml bottle
MA9062
1382 ppm calibration solution, 230 ml bottle

WARRANTY:

These instruments are warranted from all defects in materials and manufacturing for a period of two years
from the date of purchase. The electrode is warranted for a period of 6 months.
If during this period, the repair or replacement of parts is required, where the damage is not due to negli-
gence or erroneous operation by the user, please return the parts to either dealer or our offi ce and the repair
will be effected free of charge.
Note: We reserve the right to modify the design, construction and appearance of our products without ad-
vance notice.
www.milwaukeeinst.com
USER MANUAL
MILWAUKEE MC311 EC CONTROLLER
WITH MP810 1,5 L/H DOSING PUMP
mS
1.8
Smart Monitoring System

SPECIFICATIONS

MC311 EC Meter
Range
0.0 to 10.0 mS
Resolution
0.1 mS
Accuracy
±2% Full scale
Setpoint
0.8 to 2.8 mS
Alarm / Output
active when measure is
Power Socket
higher/lower than selected
setpoint depending on
user selection
Power drivers
115VAC, 2A, 60Hz
or 230VAC, 1A, 50Hz
pH electrode
MA812/2 (included)
Environment
0 to 50°C, 95% RH
not condensing
Power supply
12 VDC (included)
Dimensions
148.5 x 82.5 x 32 mm
Weight
180 g
MC740

MP810 Peristaltic Dosing Pump

• Constant Dosing fl ow of 1,5 l/h
(25 cc/min)
• No regulation
• Maximum pressure: 1 bar
• Made of Polipropilene (PP)
• Peristaltic tube in Santoprene
• Power supply: 230 VAC ± 10%

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MC740 and is the answer not in the manual?

Questions and answers

Summary of Contents for Milwaukee MC740

  • Page 1 MC740 Connect the pump to the MC311 EC controller (on the black and MILWAUKEE MC311 EC CONTROLLER white outlet). The pump will discharge 0,08 cL every 2 seconds WITH MP810 1,5 L/H DOSING PUMP when active.
  • Page 2 INSTALLATION OF CONTROLLER: CALIBRATION: Connect the supplied 240VAC/12VDC power adapter to the • Clean the probe with alcohol and let it dry (if a more thorough meter and to the main line. cleaning is required, brush the metal pins with fine sandpaper and then rinse with water).

Table of Contents