Download Print this page

Niigata seiki DEI-233S1 Instruction Manual

Digital s-line indicator?ip65?

Advertisement

Quick Links

DIGITAL S-LINE INDICATOR (IP65)
Thank you for purchasing the Digital S-Line Indicator.
For proper operation, please read this manual thoroughly before use.
PARTS IDENTIFICATION
Battery Cover
[ MODE ] Button
Accessories
C R 2 0 3 2
CR2032
( Lithium Cell )
※Included for test
BATTERY REPLACEMENT
①Remove the ( 2x ) battery screws using ( + ) PH#0
screwdriver. Place a small standard screwdriver in
the notch to gently pry open the cover and slide out
the battery.
②Insert the new battery following the polarity markings
on the cover.
③Replace Battery Cover and tighten screws to secure.
Notch
Battery Cover
NOTICE
Use only CR2032 type battery.
LCD Display
MODE
MODE
SET
SET
SWISS MADE
SWISS MADE
[ SET ] Button
Stem
( Mounting Shaft )
Spindle
Contact Point
Battery Cover
Battery
C R 2 0 3 2
INSTRUCTION MANUAL
Model No. DEI-233S1/DEI-233S2 <combined>
FEATURES
IP65 class waterproof rating
Small size
ABS and REL measurement modes
ABS mode: With Display Hold
REL mode: With one touch Preset recall
Direction of measurement ( + / − ) switchable
Preset function
Auto-off feature ( approx. 4 hour )
※REL mode only
Made in Switzerland
SPECIFICATIONS
Model No.
Measurement Range
Resolution
Displayed Resolution
Accuracy
Measurement Force
Repeatability
Preset
Measurement Dir. Switchable
Mounting Shaft Diameter
Operating Temp. Range
Power Supply
Weight
TROUBLESHOOTING
Error Condition
Err 0 is Displayed
on LCD
Measured value is
wrong
LCD does not
display
Displayed value is
unstable
Display is hard to
read
※If problem persists, or if you have any questions, please contact distributor
or place of purchase.
※Please note, manufacturer is unable to respond to inquires or provide
service directly. Please contact distributor or place of purchase.
DEI-233S1
DEI-233S2
0-12.5mm
0.01mm
0.001mm
0.01mm/0.001mm
0.01mm
( switchable )
0.02mm
0.005mm
Less than 1.5N
0.002mm
up to ±130mm
YES
φ8mm
5∼40℃
CR2032 ( Lithium cell ) ×1
70g
Corrective Action
Read Error.
Reset the sensor by pressing the
[ MODE ] or [ SET ] button.
※If message is displayed again, there
is possibility that the memory is
corrupted; Please contact distributor
or place of purchase.
Clean measuring surfaces with lens
tissue or similar.
Confirm and re-set 0-Point setting.
Cycle power by removing and
replacing battery.
Replace battery with new one.
See Reverse for How to Use →

Advertisement

loading

Summary of Contents for Niigata seiki DEI-233S1

  • Page 1 DIGITAL S-LINE INDICATOR (IP65) INSTRUCTION MANUAL Model No. DEI-233S1/DEI-233S2 <combined> Thank you for purchasing the Digital S-Line Indicator. For proper operation, please read this manual thoroughly before use. PARTS IDENTIFICATION FEATURES ● IP65 class waterproof rating ● Small size ●...
  • Page 2: Power Off

    Only use as directed. Improper use may cause accident or injury. ※If no operation is performed after 5 seconds, display Niigata seiki Co., Ltd. will return to the measurement screen. 6-15-22, Tsukanome, Sanjo, Niigata, Japan, 955-0055 Tel. : +81-256-31-5670 Fax. : +81-256-39-7730 MAIL intl.sales@niigataseiki.co.jp...

This manual is also suitable for:

Dei-233s2