Mitsubishi Electric EMU4-FD1-MB User Manual page 18

Energy measuring unit
Table of Contents

Advertisement

Procedures for setting
・ Basic operations in setting
Function
Choose setting value
confirm setting value
Go back the previous setting item
Go back to setting menu during setting
Setting mode or confirmation mode
Setting menu 4
Setting menu 5
Alarm setting
MODBUS®TCP setting / Logging setting
Use of upper /
lower limit alarm
※6
Upper / lower limit
alarm element
Upper / lower limit
alarm value
Alarm delay time
Alarm reset
method
Symbol
Transition from operating mode to setting mode.
Transition from operating mode to confirmation mode
Enter each setting display or transition to next item.
Go back to previous setting display.
No display
Memorize changed setting and transition to operating
Reset setting values to factory default.
Operation
Press
+ / PHASE
or
- / RESET
Press
SET
Press
DISP
Press
SET
※7
US®TCP
Logging module
ddress
ID
BUS®TCP
Logging data clear
net mask
confirmation
BUS®TCP
ault G/W
※1: On confirmation mode, transition to operating mode.
※2: Transition only when selecting "SP" for "Primary voltage
(VT or direct voltage)" on Setting menu 1.
※8
(For 3P4W, only special voltage is available when using VT.)
※3: Transition only when selecting "CO.P." for "Contact/pulse
BUS®TCP
input".
ault G/W
※4: Transition only when selecting "PLS" for "Contact/pulse
output".
※5: Transition only when selecting "on" for "Equivalent CO2
indication".
※6: Transition only when selecting "on" for "Use of upper/lower
DBUS®TCP
limit alarm".
Reset
※7: Transition only when connecting MODBUS®TCP module.
※8: Transition only when selecting "on" for MODBUS®TCP
Default G/W existence".
※9: Transition only when connecting logging module.
※10: Not displayed on setting mode.
※11: The following data is not cleared.
Electric energy (consumption, regeneration),
Reactive energy,
Equivalent CO2 (hide),
Operation time (hide)
When selecting "CO.P."for "Counting method of operating
Behavior
Select menu number or "End".
Select setting value.
Transition to "End" display.
mode.
Select "CANCEL".
Cancel change of setting value.
Skip other items during setting.
Press for more than one second to
fast-forward
.
After setting value is confirmed, transition
.
to next item.
.
Setting value of the last item before return
is effective.
for one second.
Setting menu 6
Test mode
※9
※10
Test mode
Operation of control button
Press both at the
"SET" + "-"
same time for 2 sec
"SET"
Press for 2 sec
"+" or "-"
Press several times
"SET"
Press once
"DISP"
Press once
"+" or "-"
Press several times
"SET"
Press once
"SET"
Press once
"+" or "-"
Press once
"SET"
Press once
"SET"
Press for 1 sec
"DISP" + "-"
Press once
(17/71)