Notes:
If a PTC resistor is fitted,
this should be connected
between 4 (+24 V) and 3
(DIN 3).
Analog Input type:
voltage input 0 – 10V.
24 V power supply = 100
mA maximum.
24 V-Versorgung
max = 100 mA .
Terminal
1
2
3
6/7
8/9
Figure 6
1.3
Avoiding Electro-Magnetic Interference
Good installation practices will ensure safe and trouble-free operation.
For further information see Operating Instructions.
2
Commissioning COMBIMASTER 411/
MICROMASTER 411
2.1
General Information
For default operation no additional equipment is required. However, for
more complex operation either the Basic Operator Panel (BOP),
Advanced Operator Panel (AOP) or Fieldbus options can be used.
These are available as non-standard options and must be ordered
separately.
When delivered the inverter has a frequency setpoint range of
between 0 Hz and 50 Hz. Regardless of its initial position the Control
Potentiometer must be turned fully counter-clockwise before the
inverter can start.
WARNING
The inverter does not have a mains power switch and is therefore live
when the power supply is connected.
Inputs
Digital Input 1 [DIN1]
Digital Input 2 [DIN2]
Digital Input 3 [DIN3]
Analog Input (-/+) [AIN]
Option: DIN4
Output Relay
Control Circuit Input Terminals
MICROMASTER 411 & COMBIMASTER 411
Getting Started Guide – 07/05
8
9
RL1-B
RL1-C
1
2
3
4
5
DIN1 DIN2
DIN3
+24V
0V
Default operation
ON/OFF1
Reverse
Fault Acknowledge
0 – 10 V Analogue Input
Fault identification
6
7
AIN-
AIN+
9