MICROMASTER 411
Getting Started Guide
This Getting Started Guide allows for easy and efficient commissioning
of the Siemens COMBIMASTER 411 and MICROMASTER 411
Inverters.
For further technical information, please refer to the Operating
Instructions and the Parameter List on the CD-ROM supplied with
COMBIMASTER 411 and MICROMASTER 411.
Contents
1
1.1
1.2
1.3
2
2.1
2.2
3
3.1
3.2
3.3
3.4
4
4.1
4.2
MICROMASTER 411 & COMBIMASTER 411
Getting Started Guide - 07/05
English
Issue 07/05
3
3
7
9
9
10
15
15
16
16
16
16
16
17
1

Advertisement

Table of Contents
loading

Summary of Contents for Siemens COMBIMASTER 411

  • Page 1: Table Of Contents

    Getting Started Guide Issue 07/05 This Getting Started Guide allows for easy and efficient commissioning of the Siemens COMBIMASTER 411 and MICROMASTER 411 Inverters. For further technical information, please refer to the Operating Instructions and the Parameter List on the CD-ROM supplied with COMBIMASTER 411 and MICROMASTER 411.
  • Page 2: Combimaster

    See Operating Instructions for recommended tightening torques. If a Residual Current-operated protective Device (RCD) is to be used, it must be an RCD Type B. COMBIMASTER 411 & MICROMASTER 411 cannot be used on unearthed power supplies (IT). CAUTION Children and the general public must be prevented from...
  • Page 3: Installation

    To ensure safe operation of the inverter, it must be installed and commissioned by qualified personnel in full compliance with the warnings laid down in the COMBIMASTER 411 and MICROMASTER 411 operating instructions. Take particular note of general and regional installation, and safety regulations regarding work on dangerous voltage installations (e.g.
  • Page 4 17. Place the inverter cover onto the assembled terminal housing. 18. Secure the inverter cover with the four M5 captive screws. Use either a 4-5 mm flat bladed screwdriver or a 2pt Pozidrive Head screwdriver. MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 5 1.1.3 Installation of Cable Glands WARNING MICROMASTER 411/COMBIMASTER 411 is not suitable for connection to rigid conduit systems. Use flexible cables (CY and SY types) for motor output and flexible cables or flexible conduit for mains input or control connections.
  • Page 6 Power Supply Terminals Filter Module Output Relay Cable Gland Terminals (Control) Input/Output Board Control Terminals (Cable glands shown in preferred positions) Figure 3 MICROMASTER 411 Terminal Housing (Case Size B) MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 7: Electrical Installation

    9. Ensure the appropriate circuit breakers/fuses with the specified current rating are connected between the power supply and the inverter. See Section 7.5 of the Operating Instructions for further details. MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 8 3. Connect the control wires in accordance with the terminal information given in Figure 6. 4. Use screened cable for all control wiring. Cable connections for Control Terminals are as given in Figure 6. MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 9: Avoiding Electro-Magnetic Interference

    Potentiometer must be turned fully counter-clockwise before the inverter can start. WARNING The inverter does not have a mains power switch and is therefore live when the power supply is connected. MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 10: Commissioning Procedure Overview

    Commissioning Procedure Overview COMBIMASTER 411 and MICROMASTER 411 can be commissioned in a variety of ways as explained in sections 2.2.1 to 2.2.6 below. Mechanical Installation Installation Electrical Installation Default Command Source DIN1 Parameter ON/OFF1 P0700 = 1 Jumper: Pot = Run...
  • Page 11 Using up to 5 jumpers allows ramp times to be set between 1 to 240 secs. See table below for details of settings: Table 2 Ramp Times Using Jumpers Time X 10 X 20 100s 120s 140s 150s 160s 180s 210s 240s MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 12 With the DC Brake Jumper set, when stopping the inverter, DC Braking is applied for a period proportional to the Ramp Down Time. Frequent use of long periods of DC injection braking can cause the motor and inverter to overheat. MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 13 If the unit is powered up when the Control Potentiometer is not in the OFF position, the unit may automatically restart and ramp-up to the frequency setpoint (Auto-restart function is active by default. MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 14 Switch off the inverter if the fault condition persists. For further fault code designations, please refer to the COMBIMASTER 411 and MICROMASTER 411 Operating Instructions on the CD included with the inverter. MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 15: Quick Commissioning

    Commissioning with BOP Motor parameters detailed below are already set for the respective Siemens motor at the factory. In order to change parameter settings, use either a BOP/AOP or a Commissioning Tool (e.g., Drive Monitor). The parameter sequence below ensures optimized and efficient operation of the inverter.
  • Page 16: Reset To Factory Defaults

    Reset to Factory Defaults For factory default settings set P0970 to 1 (with P0010 = 30). Where the inverter is integrated with a non-Siemens motor, setting P0970 = 1 restores the default parameter settings for the respective motor. CAUTION The reset process can take up to 3 minutes to complete.
  • Page 17: Combimaster 411 - Dimensions

    2-CSC Inverter 3-Control Potentiometer 4-Fixing 5-Comms Interface Figure 13 Dimensions COMBIMASTER, Case Size C NOTE: For details of motor construction (feet and flange dimensions) please refer to the Operating Instructions. MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 18: Micromaster 411 & Combimaster

    NOTES MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 19 NOTES MICROMASTER 411 & COMBIMASTER 411 Getting Started Guide – 07/05...
  • Page 20 ISO 9001 Siemens plc operates a quality management system, which complies with the requirements of ISO 9001. To submit any suggestions for improvements, please visit the Siemens Standard Drives Web Site at http://www.siemens.de/micromaster Siemens plc Automation & Drives...

This manual is also suitable for:

Micromaster 411

Table of Contents