 Operand [S1] setting
• Specify the starting address storing the setting number (string) and send trigger or a
character constant.
Setting
Settings
item
Setting
S1
No.
 Operand [S2] setting
• Specify the device address storing the text.
• * When IDx is specified for S1, the number of bytes can be specified up to 4096 bytes. An
operation error occurs when it exceeds 4096 bytes.
 Example of processing
Example)
- Image of mail text
Floor A: 25°C
Floor B: 28°C
S1="ID5" S2=DT200
DT200
DT201
DT202
H 6F (o)
DT203
H 20 (SPACE)
DT204
DT205
H 32 (2)
H C2 (°)
DT206
DT207
H 43 (C)
DT208
H 0A (LF)
DT209
DT210
H 6F (o)
DT211
H 20 (SPACE)
DT212
H 32 (2)
DT213
H C2 (°)
DT214
H 43 (C)
DT215
Specify a setting number.
Even mail send setting number: Idx
H 001E
H 6C (l)
H 3A (:)
H 20 (SPACE)
H 0D (CR)
H 6C (l)
H 3A (:)
H 20 (SPACE)
6.3 How to Use Event Mail Transmission
No. of bytes
H 46 (F)
H 6F (o)
H 72 (r)
H 41 (A)
H 35 (5)
H B0 (°)
Data part
H 46 (F)
H 6F (o)
H 72 (r)
H 42 (B)
H 38 (8)
H B0 (°)
Setting
range
0 to 15
6-35