Mail Transmission Function
Subjects automatically generated
Subject automatically generated
bit on detect (R100)
Interval mail (1minute)
Interval mail (24hour)
Specified Time (Every Minute 0s)
Specified Time (Every Hour 0m0s)
Specified Time (Every Day 17h30m0s)
Specified Time (Every Friday 17h30m00s)
PLC status change (Power On)
PLC status change (Prog > Run)
PLC status change (Run > Prog)
PLC status change (Operation stop error)
PLC status change (Operation continuous error)
PLC status change (Error release)
SMTPcREQ command
(Note 1): When multiple "PLC status change" settings has been specified as send triggers, the subject automatically
generated is the PLC status change that is actually detected.
(Note 2): The language used for subjects automatically generated is specified in the mail server setting.
Setting example
Example 1
S2
Settings
Example 2
S2
Settings
Example 3
S2
Settings
 Operand [S3] setting
Specify the starting address storing the mail text setting to be sent or a character constant.
Enter a mail text within one-byte 256 characters.
Setting
Settings
item
S3
Mail text
6-28
"GRPNO=0,SUBJECT=Time Notify Mail"
Destination group number: 0, Subject, User-specified subject "Time Notify Mail"
"GRPNO=1+3+4+7,SUBJECT= "Cyclic Notify Mail"
Destination group numbers: 1, 3, 4, 7, Subject, User-specified subject "Cyclic Notify Mail"
"GRPNO=0+1+2+3+4+5+6+7,SUBJECTAUTO"
Destination group numbers: 0 to 7, Subject: Automatically generated
Specify the starting address storing the mail text setting to be
sent or a character constant.
Setting
range
Max. 256
characters