Setting The Gas Pressure - Miele CS 1018 G Operating And Installation Instructions

Gas wok burner
Table of Contents

Advertisement

Setting the gas pressure

The gas pressure must be set by the
approved gas fitter as shown on the
data plate:
Natural gas 1.0 kPa
ULPG (Propane/Butane) 2.75 kPa
The gas pressure must be set with the
largest burner operating at maximum
setting.
a Connection R ¹/₂" with test point
b Connection R ¹/₂" with test point and
90° angle
When using a 90° angle the building-
in depth will increase to the depth of
the elbow used.
The gas regulator is only included with
appliances which are set up for
connection to natural gas.
a Pressure Test Point
 Loosen the screw in the test point
a
 Connect the hose from the pressure
 Reassemble one of the large burners,
b
 Disconnect gauge and screw in the
Gas connection
a
until it is free in its housing. The
screw is retained in this position.
gauge.
turn on the gas and manually light the
burners.
test point screw.
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents