Connection to the gas supply, or
conversion from one type of gas to
another should only be undertaken
by an approved gas fitter, who is
responsible for correct functioning of
the appliance when installed. Every
appliance should have its own
isolating valve.
The gas connection must be
installed so that connection can be
made either from inside or outside
the kitchen unit, and the isolating
valve must be easily accessible and
visible (by opening one of the kitchen
unit doors, if necessary).
Check with your local gas supplier
about the type of gas and its calorific
value, and compare this information
with the type of gas quoted on the
appliance data plate.
This appliance is not connected to
an exhaust flue. Please ensure it has
adequate ventilation after installation.
When installing and connecting the
appliance observe the relevant
regulations, especially appropriate
ventilation.
The gas connection must be in
accordance with national and local
regulations.
Special provisions of the local gas
supplier, as well as the relevant
building regulations, must also be
observed.

Gas connection

The gas connections the gas hose
and the mains connection cable can
get damaged when they become
hot.
Ensure that the gas hose and
electrical cable are installed in such a
way that they do not touch any parts
of the appliance which become hot
and that the gas hose and gas
connection do not come into contact
with hot gas exhaust.
Flexible hoses can be damaged
when installed incorrectly.
Ensure the hose assembly is not
exposed to high temperatures
exceeding the maximum
recommended by the hose
manufacturer, subjected to strain,
kinking, permanent deformation or
damage by vermin.
Unsuitable sealants do not guarantee
the required impermeability of the
connection.
Use only suitable sealants.
The gas pressure must be set by an
approved gas fitter and a full
operational test and a test for
possible leakages must be carried
out by the gas fitter after installation.