E3G080 Control module "Extinguishing"

37.10 Connections

1,2
1)
5.6
4k75
3.4
illuminated
6)
1)
4k75
warning panel
only valid to EP5
E3G080
Terminal block
Sector valve
(delayed)
Main valve
(undelayed)
Alarm horn monitored
steady / pulsating
Illuminated warning panel
monitored
(steady / pulsating)
Manual activation
0V
Stop- or blocking button
Module chassis ground
Loss of extinguishing agent
0V
Exting. blocked / Emergency stop
0V
Extinguishing activated
0V
Extinguishing control console
B3Q440 (LON interface)
Interlocking with other E3G080
Plug-in terminals
Supply for
I-Bus modules
F7
Double flat cable header
Data communication
I-Bus modules
Notes:
1) The polarity indicated at terminals 4...7 applies to active status.
2) Instead of the alarm resistor (1k2) A Z diode (5.6 V) can also be inserted for the stop/blocking button.
3) Choice of make or break contact. Zener diodes forbidden!
4) Max. 600m between E3G080 and one B3Q440 with a wire gauge of 0.8mm (twisted);
- with several B3Q440 on the same stub line, correspondingly shorter,
- the deciding factor is the maximum current per B3Q440,
- in the supply line to the last B3Q440, a voltage drop of max. 6 V is permissible.
5) If control lines / detection lines are not used, a termination resistor need not be connected.
6) only valid for EP5: For change of tone, depending on alarm horn, use either the positive pole of the "Illuminated warning panel" output,
or intermediate relay
158
Building Technologies
Fire Safety & Security Products
AGN24.5
24V max. 2A
4k75
24V max. 2A
4k75
6)
X10
+
1
F11
24V max. 2A
-
2
24V max. 2A
+
3
F13
+
4
F14
1)
4k75
-
5
+
6
F16
1)
4k75
-
7
8
9
10
(connect to
11
chassis ground)
12
max. 150Ω
13
14
max. 150Ω
15
16
max. 150Ω
17
A
18
R151
B
19
20
to other E3G080
24V from the control unit
(E3X10. / AlgoPilot 'K7')
K1
1
-
blue
GND
2
-
blue
5V
+
3
green
24V
+
4
red
ST1
Horn universal
4+
5-
6+
illuminated
7-
warning panel
can be calibrated 16...320Ω
can be calibrated 16...320Ω
AGN24.5 or horn universal
illuminated warning panel
Z5.6V
1k2
2)
4k75
5)
1k2
3)
4k75
1k2
3)
4k75
1k2
3)
4k75
+
Ground
-
max. 600m
from previous I-Bus modules
to other I-Bus modules
from previous I-Bus modules
to other I-Bus modules
1,2,3
5
12
AGE24
4k75
6)
13
4
6,7
illuminated
4k75
warning panel
Z5.6V
2)
4k75
B3Q440
4)
ST22
ST21
ST11
ST12
ST13
001260_k_en_--.doc