Kingfisher KI 6680 User Manual
Kingfisher KI 6680 User Manual

Kingfisher KI 6680 User Manual

Fiber inspection probe
Hide thumbs Also See for KI 6680:

Advertisement

Quick Links

Table of Content
1. Introduction ................................................................................................................................
2. Instrument Overview ................................................................................................................
2.1. Features: ................................................................................................................................................................ - 2 -
2.2. Layout: ................................................................................................................................................................... - 2 -
2.3. Specification and Standard Accessories: ...................................................................................................... - 3 -
3. Instrument Basic Operation ....................................................................................................
3.1. Charging instrument .......................................................................................................................................... - 3 -
3.2. Replacing instrument battery .......................................................................................................................... - 3 -
3.3. Installing Inspection Adaptor .......................................................................................................................... - 4 -
3.4. Torch LED ............................................................................................................................................................. - 5 -
4. Viewing Image on Smart Devices (via WiFi connection only) ..........................................
4.1. Download Software ............................................................................................................................................ - 5 -
4.2. Connect Instrument to Smart Devices .......................................................................................................... - 5 -
4.3. Imaging Software Operation .......................................................................................................................... - 6 -
4.4. To Captured and Save Images on Smart Devices ..................................................................................... - 6 -
5. Viewing Image on PC (via WiFi or USB connection) ..........................................................
5.1. Download Software ............................................................................................................................................ - 8 -
5.2. Connect Instrument to PC ............................................................................................................................... - 8 -
5.3. Imaging Software Operation ........................................................................................................................... - 9 -
5.4. To Captured and Save Images on PC ........................................................................................................ - 10 -
6. Pass/fail Acceptance Guidelines ...........................................................................................
7. Eye Safety Precaution .............................................................................................................
8. Care of Your Instrument .........................................................................................................
9. Service and Support ................................................................................................................
10. Disclaimer and Warranty ......................................................................................................
11. Ordering Information .............................................................................................................
12. Optional Interchangeable Inspection Adaptors ...............................................................
Revision 4
KI6680, Mini Fiber Inspection Probe User Manual
Date: 31/05/2018
- 2 -
- 2 -
- 3 -
- 5 -
- 8 -
- 10 -
- 10 -
- 10 -
- 10 -
- 11 -
- 11 -
- 11 -
Page 1 of 12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KI 6680 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kingfisher KI 6680

  • Page 1: Table Of Contents

    KI6680, Mini Fiber Inspection Probe User Manual Table of Content 1. Introduction ..........................- 2 - 2. Instrument Overview ........................ - 2 - 2.1. Features: ................................- 2 - 2.2. Layout: ................................... - 2 - 2.3. Specification and Standard Accessories: ...................... - 3 - 3.
  • Page 2: Introduction

    KI6680, Mini Fiber Inspection Probe User Manual 1. Introduction The KI6880 Mini Fiber Inspection Probe is a handy tool to check fiber optic connector end face quality. The end face image can be viewed and stored on Windows, Android or iOS devices via USB or WiFi connection.
  • Page 3: Specification And Standard Accessories

    Battery connection error 3.2. Replacing instrument battery The instrument is powered by a specific built-in Lithium battery which could be replaced as shown below. Contact Kingfisher for replacement battery. ➊ Remove 2 screws, using a special screw driver, to open battery door ➋...
  • Page 4: Installing Inspection Adaptor

    KI6680, Mini Fiber Inspection Probe User Manual 3.3. Installing Inspection Adaptor Place an inspection adaptor onto instrument’s adaptor head, make sure that the pin is aligned into the groove, tighten locknut on adaptor head by turning it in the direction shown in diagram below. Adaptor head Turn locknut to tighten...
  • Page 5: Torch Led

    KI6680, Mini Fiber Inspection Probe User Manual 3.4. Torch LED The built-in Torch LED on instrument can be turned on to assist works in dark or low light conditions. To turn light on, flip Torch LED on/off Switch to “ ”. To turn off, flip the switch to “ ○...
  • Page 6: Imaging Software Operation

    KI6680, Mini Fiber Inspection Probe User Manual 4.3. Imaging Software Operation Tab icon, on your Smart Device to start the imaging software. Turn Focus Ring (clockwise / anticlockwise) of instrument to obtain a sharp image on the Main Display, see figure below for associated menus and their respective functions.
  • Page 7 KI6680, Mini Fiber Inspection Probe User Manual Alternatively, Press the Image Capture Button on instrument to capture & save image. Image capture button on instrument Note: this button does not work in USB mode Image Capturing symbol • To capture and save images in files with preferred file names: On Main Menu (see figure in section 4.3.), select “General Setting”, and follow the steps below.
  • Page 8: Viewing Image On Pc (Via Wifi Or Usb Connection)

    KI6680, Mini Fiber Inspection Probe User Manual 5. Viewing Image on PC (via WiFi or USB connection) 5.1. Download Software See section 2.3 for Software Compatibility on PC. Download the software, “Imaging Software-PC” from https://www.kingfisherfiber.com/products/fiber-inspection-scope/ki-6680-fiber-inspection-probe your PC. Install the software as per the prompted instructions. 5.2.
  • Page 9: Imaging Software Operation

    KI6680, Mini Fiber Inspection Probe User Manual 5.3. Imaging Software Operation Double click on icon, “EasyGetWiFi” on your PC to start the imaging software. The main display below will show up. Follow the steps below to connect instrument to software. ➊...
  • Page 10: To Captured And Save Images On Pc

    KI6680, Mini Fiber Inspection Probe User Manual 5.4. To Captured and Save Images on PC Click on “Capture” button (see figure above) to capture and save images on PC using default or preferred file names as described in the figure. Alternatively, press Image Capture Button on instrument to capture and save images when connected in WiFi mode.
  • Page 11: Disclaimer And Warranty

    This manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against Kingfisher International or its representatives. This product is guaranteed against defective components and workmanship for 1 years from delivery, unless stated in the purchase contract. This warranty excludes connector adaptors or incorrect use.
  • Page 12 KI6680, Mini Fiber Inspection Probe User Manual Scan to download iOS version of imaging software, KI6680 Img Viewer Scan to download Android version of imaging software, KI6680 Img Viewer Revision 4 Date: 31/05/2018 Page 12 of 12...

Table of Contents