Download  Print this page

Toshiba PCT001Z-E Instruction Manual page 10

Trace tool
Hide thumbs

Advertisement

④ Inverter individual information
'Inverter form': Displays the type of the inverter.
'Serial number': Displays the serial number of the inverter.
'CPU1 Ver': Displays the version of the inverter's CPU1.
'CPU2 Ver': Displays the version of the inverter's CPU2.
'Inverter operating time': Displays the operating time of the inverter.
⑤ [Parameter export]
Click this button to write the values set for the trace-related parameters (Fig. 7) into the
inverter.
⑥ [Parameter import]
Click this button to read the values set for the trace-related parameters (Fig. 7) and
information on the inverter (Fig. 8).
⑦ [To graph >]
Click this button to move from the Setting sheet to the Graphic sheet.
⑧ [A set value of constant at the time of filtering is not changed.]
If this radio button is checked, clicking [Parameter export] will not change the value of
constant at the time of filtering. (Select this option under normal conditions.)
⑨ [Recommended value of constant at the time of filtering is set by the automatic set up.]
If this radio button is checked, clicking [Parameter export] will write the value of constant
at the time of filtering recommended for the trace cycle into the inverter. The value set
with F678 (constant at the time of filtering), however, does not take effect.
The table below shows correspondences between trace cycle and recommended value
of constant at the time of filtering.
Table 3 Correspondence between trace cycle and recommended value
of constant at the time of filtering
Trace cycle
Constant at the time of filtering
Fig. 8 Inverter individual information
4ms
4ms
8
20ms
100ms
1s
10ms
64ms
64ms
E6581478
*5
10s
64ms

Advertisement