NOTES FOR ALL HEATERS
Heater Guard Fence:
A non-metallic guard (not included) shall be provided and installed as follows:
a)
4" from CW Series heaters
b)
6" from FM Series heaters
Sauna Rocks (included):
1)
Wash the rocks before placing on heater.
2)
Do not pack rocks too tightly into rock tray. There should be pockets of air. Stack
rocks loosely in a "pyramid" like pile. Packing rocks too tightly will trap heat and
cause the hi-limit to trip.
3)
These units must not be operated without the igneous rocks in place
Water:
Do not soak the heater with water. Water should be used in moderation Sprinkling with a ladle is
recommended.
Manual Reset High Limit Control:
1)
This safety device must not be by-passed in the wiring of this sauna heater.
2)
Should the high temperature limit control trip frequently, a qualified serviceman should be
contacted.
A licensed electrical contractor should do all electrical work.
Do NOT use a G.F.I breaker.
All cables used in the installation of these units must be rated for 300 VAC.
All cables supplied and connected to these units must be rated for 90
When using the sauna for the first time it is normal to have a little smoke. The elements are
burning off oil residue left by the manufacturing process. Turn the sauna on for ½ hour,
leave the door open and do not go inside.
Sauna Craft CTT Heater

Installation Manual

FIRST TIME USE
o
Celsius.

Advertisement

loading
Need help?

Need help?

Do you have a question about the CTTS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sauna Craft CTTS

  • Page 1: Installation Manual

    Sauna Craft CTT Heater Installation Manual NOTES FOR ALL HEATERS Heater Guard Fence: A non-metallic guard (not included) shall be provided and installed as follows: 4” from CW Series heaters 6” from FM Series heaters Sauna Rocks (included): Wash the rocks before placing on heater.
  • Page 3 CTT heaters have controls built into the front bottom of heater Circuit Circuit Field install contactor in Breaker Breaker 664 enclosure provided. (Not suitable for wet area. Use weather proof box if installing inside sauna or outdoors.) Contactor Sauna Heater controls pre-wired Contactor Coil...
  • Page 4 CTT INTERNAL WIRING 7.5 & 9 kW (with separate contactor) CTT INTERNAL WIRING 4 to 6 kW Heater High Limit T3(n/a) Timer Timer Heater High Limit Timer T3(n/a) Timer Thermostat High Limit capillary DO NOT TOUCH Thermostat Connect to Contactor Supply Connect To High Limit capillary DO NOT TOUCH...
  • Page 5: Sauna Rock Placement-Sc

    The rocks should filled as indicated below: CWS, CWM (Figure 10): Fill center and one side chamber. Leave the other side chamber open. CW-XR (Figure 12): Fill center. Leave side chambers open. . 12. MODEL: CTT-XR 10. MODEL: CTTS, CTTM...
  • Page 6 If outlet is exterior wall, you must run duct or construct a chase through stud cavity and over drop ceiling. Exhaust into room in front of sauna. 1. Inlet vent installed behind heater approx. 6" above floor. Cut opening or drill ho terior: use painted aluminum grill (not supplied) 2.
  • Page 7 SAUNA TROUBLE SHOOTING Problem Probable Cause Remedy Note: Except where noted otherwise, reference to control refers to TPT3 mechanical control Heater will not start Control wired incorrectly Check wiring diagram carefully to ensure control circuit is wired correctly High temperature control has tripped Using pencil or other non-condutive material, carefully push in "reset"...
  • Page 8 This is normal. Leave the door open and allow the sauna to run about 30 minutes. Technical Support Contact Information Before calling, please review the trouble- Sauna Craft shooting guide in this manual. When calling 115 Bowes Rd, Unit 2 please have the following information: Concord, ON...