1.15.3 Replacing A Hard Disk Drive In The Raid System - NEC N8100-1998F User Manual

Express / express5800 series
Table of Contents

Advertisement

Chapter 2 Preparations

1.15.3 Replacing a hard disk drive in the RAID system

In the RAID system, you can use the auto rebuild feature to restore the data back to the state before the
failure.
The auto rebuild feature is enabled in logical drives set to RAID 1, RAID 5, RAID 6, RAID 10, and RAID 50.
The disk is automatically rebuilt when hot swapping a failed hard disk drive.
During the auto rebuild, the DISK LED on the hard disk drive flashes green and amber alternately to indicate
that auto rebuild is being performed.
Observe the following precautions whenever executing auto rebuild.
Do not turn off the server until auto rebuild completes.
Leave an interval of at least 90 seconds between a hard disk drive removal and a hard disk drive
installation.
Do not replace another disk during the auto rebuilding.
Express5800/R110f-1E User's Guide
1. Installing Internal Optional Devices
97