Automatic Heating/Filtration
The XS-3000's intelligent software constantly monitors the spa
water, automatically controlling the heater and circulation pump to
ensure the desired set water temperature is maintained and
required level of daily filtration achieved. The user can adjust the
o
o
o
set temp point from 5 C - 40 C (Default: 38 C).
Display Modes
The XS-3000 has four possible display modes:
1.
W.TMP Water Temperature (actual)
2.
S.TMP
Set Temperature
3.
TIMR
Timer Mode
4.
TIME
Time Clock
The default display mode is
W.TMP
(
refer
below)
has a different icon to indicate the display mode being viewed.
W.TMP Display Mode Icon
Default Display
OFF
ON
10 : 30
Water Temperature
AM
PM
(W.TMP)
SA SU
MO
TU WE TH FR
Set Temperature
Time & Day
Actual Water Temperature
If the optional In-Pool Temperature Sensor is NOT connected the
default display mode is usually set to
S.TMP
Press the
UP
and
DOWN
buttons to scroll through the different
display modes. As you scroll through each mode a brief title
screen is shown followed by the actual display mode.
Use to scroll
through display
OK
modes
Quick Start
Adjusting Set Temperature
GUIDE
Unless adjusted the XS-3000 will automatically heat to and
maintain the default temperature of 38 C. This set point can be
adjusted from 5 C - 40 C in steps of 0.2 C increments.
OK
S.TMP Display Mode Icon
38 . 0 0
OFF
ON
10 : 30
SA SU
MO
OK
. Each mode
OK
Timer Mode
°C
°F
TIMR Display Mode Icon
MODE
SPD
20 : 0 0
BRT
3 8.0
°C
°F
SET TEMP
OFF
ON
10 : 30
Current
SA SU
MO
TU WE TH FR
OK
.
(Set Temperature)
3. The countdown time period will begin to flash. Use the
DOWN
confirm and begin countdown => at expiry of time period the
alarm will emit 15 beeps and then turn off.
Note: The Timer icon is displayed in ALL display modes when in use. The TIMR
screen will timeout after 10 secs and revert to the default display mode. The Timer
can be cancelled at any time by returning to the TIMR display mode (countdown
will be shown) and pressing the OK button.
o
o
o
o
Hold either
UP or DOWN
1.
HOLD
the
UP
button to begin
button to begin adjusting
temperature
the set temperature.
adjustment
2. The screen will toggle to
the
S.TMP
(
°C
mode and the set
°F
MODE
SPD
temperature point will
BRT
3 8.0
begin adjusting.
°C
AM
°F
PM
TU WE TH FR
SET TEMP
will flash indicating
adjustable set temp mode.
Use to adjust
temperature
3. Use the
UP
and
buttons to adjust the set
temperature to your
desired setting.
Press OK to
save setting
4. Press
OK
to confirm and
save the new setting
1. Use the
UP
and
°C
°F
button to toggle the
MODE
SPD
BRT
screen to the
TIMR
3 8.0
°C
AM
PM
°F
display mode.
SET TEMP
2. Press the
OK
button to set
Press OK to
the countdown timer.
set Timer
buttons to select your desired time period. Press
Setting the Time Clock
TIME Display Mode Icon
10 : 30
OFF
ON
SAT SUN MON
TUE
WED THU FRI
or
DOWN
Press & hold
OK
for 3 seconds
3. The screen will then prompt for selection of 12 or 24 hour format.
) display
Use the
UP
and
DOWN
press
OK
to confirm. Repeat step 3 to set day / hours / minutes.
The digits
Use to adjust
OK
settings
DOWN
Diagnostics / Error Codes
Please note most error conditions require the spa control to be powered
OFF
and then back
ON
before the error is cleared.
Scrolling Message
1
.
2
"ER-2 HEATER PLUG"
3
"ER-3 WATER PRIME"
4
"ER-4 THERMAL TRIP"
DOWN
(
)
5
"ER-5 POOL TOO HOT"
6
"ER-6 HEATER SENSOR"
7
"ER-7 POOL SENSOR"
UP
and
8
"ER-8 CONTROLLER"
OK
to
WATER CHEMISTRY MAINTENANCE:
and maintain the chemical water balance of the spa pool to ensure it remains within
reasonable pH (acid/alkaline) limits => (7.4 - 7.6 pH). Unbalanced water chemistry
greatly accelerates corrosion and may lead to early product or component failure.
Product or component failures caused as a result of poor water chemistry
maintenance will NOT be covered by the SpaNET Product Warranty.
1. Use the
UP
and
DOWN
button to toggle the
AM
MODE
screen to the
TIME
(
)
SPD
BRT
display mode.
2. Press the
OK
button to
adjust the current time.
buttons to select the correct setting and
Press OK to
OK
confirm setting
Description
All systems are fine.
Heater sensor cable fault
Check that the heater sensor lead is
plugged into the spa control
Water prime failed
Press Pump A to retry the water prime
Check: Spa water level (refill if necessary)
Heater thermal trip operated
Turn power off and wait approx. 10 min
then turn power back on. Check: low water
flow through the heater, pump not running,
clogged filter, valves not fully open
Pool over temperature
o
Temperature sensor reading = > 45
C
Turn power off and allow spa to cool
Check: Daily filtration time – reduce setting
Heater sensor failure
Contact your local dealer or spa reseller
In-pool temperature sensor unable to
communicate with spa control
Contact your local dealer or spa reseller
Internal controller fault detected
Contact your local dealer or spa reseller
It is your responsibility to regularly check
TM
Need help?
Do you have a question about the XS-3000 and is the answer not in the manual?
Questions and answers