Dynabrade 58611 Safety, Operation And Maintenance Instructions

Dynabrade 58611 Safety, Operation And Maintenance Instructions

Dual-grip ros 6" diameter, central vacuum

Advertisement

Quick Links

Dual-Grip ROS
6" Diameter, Central Vacuum
Safety, Operation and Maintenance – Save This Document and Educate All Personnel
Shroud
Hose Assy.
58611
Overskirt
58612
Lip Seal
58651
Overskirt
58652
Lip Seal
SANDER / POLISHER
Find The Most Current Offering of Support Documents and Accessories at www.Dynabrade.com
Read and understand this tool manual before operating your air tool. Follow all safety rules for the protection of operating personnel as
well as adjacent areas. Always operate, inspect and maintain this tool in accordance with the American National Standards Institute (ANSI).
Safety Requirements for the Use, Care and Protection of Abrasive Wheels – ANSI B7.1, Compressed Air and Gas Institute (CAGI) Safety Code
for Portable Air Tools – B186.1, Code of Federal Regulation – CFR 29 Part 1910, International Organization for Standardization (ISO) Hand
Held Non-Electric Power Tools – Safety Requirements and applicable State and Local Regulations.
Read and understand tool manual before work starts
to reduce risk of injury to operator, visitors, and tool.
Ear protection to be worn when exposure to sound,
exceeds the limits of applicable Federal, State or
local statues, ordinances and/or regulations.
Respiratory protection to be used when exposed to
contaminants that exceed the applicable threshold
limit values required by law.
Some dust created by sanding, grinding, drilling, and other construction activities contain chemicals known to cause cancer, birth defects
or other reproductive harm. Some examples of these chemicals are:
• Lead from lead-based paints
• Crystalline silica from bricks and cement and other masonry products
• Arsenic and chromium from chemically treated lumber
Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles.
Carefully Read and Understand the General
and Sander sections found in Tool Safety
and Operating Guidelines (PN00001676)
Before Handling or Using Tool.
Tool Intent: Dual-Grip Central Vacuum Random Orbital Sander is ideal for sanding various materials using 6" hook-faced sanding pads and 6"
loop-faced coated or non-woven nylon abrasives.Tool maybe held either by one hand on the motor housing or two hands, one on the motor housing
and the second hand on the throttle handle. Follow applicable State and Local Regulations when vacuuming and when disposing of debris.
DO NOT USE Tool for Anything Other Than Its Intended Applications.
Training: Proper care, maintenance, and storage of your air tool will maximize tools performance and reduce chance for accident.
Employer's Responsibility: Provide operators with safety instructions and training for safe use of tools and accessories.
Report to Your Supervisor any Condition of the Tool, Accessories or Operation you Consider Unsafe.
RPM Orbit Dia.
3/16"
12,000
(5 mm)
Yes
WARNING

SAFETY and OPERATING INSTRUCTIONS

Eye protection must be worn at all times, eye
protection to conform to ANSI Z87.1.
Practice safety requirements. Work alert, have proper
attire, and do not operate tools under the influence
of alcohol or drugs.
Air line hazard, pressurized supply lines and flexible
hoses can cause serious injury. Do not use damaged,
frayed or deteriorated air hoses and fittings.
Carefully Read all instructions before operating or servicing any
Dynabrade
®
Abrasive Power Tool. Products offered by Dynabrade
are not to be modified, converted or otherwise altered from
the original design.
PD16.21R
January, 2017
Supercedes PD16.21
58612

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 58611 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dynabrade 58611

  • Page 1 Lip Seal SANDER / POLISHER 58612 Find The Most Current Offering of Support Documents and Accessories at www.Dynabrade.com WARNING Read and understand this tool manual before operating your air tool. Follow all safety rules for the protection of operating personnel as well as adjacent areas.
  • Page 2 After maintenance is performed on tool, add a few drops of 95842 is recommended. Dynabrade Air Lube to the tool inlet and start the tool a few times to MAINTENANCE SCHEDULE lubricate air motor. Verify RPM (per 20 hr maintenance schedule), Maintenance schedules depend on the type and style of tool.
  • Page 3 Dual-Grip ROS Model 58611 Overskirt Complete Assembly 58612 Lip Seal 58651 Overskirt, Hose Assy 58652 Lip Seal, Hose Assy ITEM DESCRIPTION QTY. 54328 HOOK-FACE PAD 57371 OVERSKIRT SHROUD – 58651 57369 LIP SEAL SHROUD – 58652 56482 MOTOR ASSEMBLY 57069...
  • Page 4: Machine Specifications

    LIFETIME WARRANTY To validate Dynabrade Lifetime Warranty, you must register each tool at: www.dynabrade.com. Registration of each tool at website is required. Dynabrade will not honor Lifetime Warranty on unregistered tools. Please view the entire Lifetime Warranty Policy at : www.dynabrade.com.

This manual is also suitable for:

586125865158652

Table of Contents