Fig. M18
Note:
Do not touch the outside circumference of the rotor surface with any tool and keep
magnetic material away from the rotor magnet (especially metal particles).
(Confirmation)
1. Supply a Video Signal to the Video Input Jack on the rear side of the deck.
2. Insert a cassette tape and place the unit in SLP recording mode.
3. Connect the oscilloscope to Pin 15 of P2502 on the Capstan Motor Drive C.B.A..
Confirm that the signal level is greater than 10mVp-p.
4.1.3.10. REPLACEMENT OF CAPSTAN ROTOR OR STATOR UNIT
75