Fig. 12-3
Type B
(Removal)
Open the Trap Connector, and pull out the Flat Cable.
Minimize stress by holding it securely to avoid damage of the individual wires. (See
Fig.
12-4.)
(Installation)
Adjust the position of the Flat Cable so that the Identification
Line on the Flat Cable aligns with Pin 1 of the Trap Connector and align the individual
wire with its individual Trap Connector Hole. Then insert the Flat Cable wire into the
Trap Connector and close the Trap Connector.
31