5. To rewind the tape into the cassette, turn the Capstan Pulley counterclockwise as
shown in
Fig.
7-3.
6. Then eject the Tape using the DC Power Supply again.
7. After completion of the procedure, resolder the jumper wire (J6004) that was
opened.
B. Manual Method
1. In the order described in the Disassembly of Cabinet Parts Section, remove the
Fig. 7-2
Fig. 7-3