46
ERROR MODE / POWER FAIL RECOVERY / DEFAULT DRYER SETTINGS
ERROR MODE
■ Meaning of Error Codes that LED displays during occurrence or
problem.
Dryer error code
PROBLEM
It is displayed when thermistor is opened or
shorted
It is displayed when thermistor temperature
have increased about 17 degrees for 10 sec-
onds
Disconnection of card reader wire.
POWER FAIL RECOVERY
In case of power failure the machine stops running but the time display remains on, showing the time just before
power failure.
Press the Start button after the power is restored, then the machine will restart.
DEFAULT DRYER SETTINGS
Default Settings
Cycle Time (Minutes)
Cool Down Time Cycle
High Temperature
Medium Temperature
Low Temperature
Top Off Time (Minutes per coin)
Coin #1 Value
Coin #2 Value
Minutes/Minutes and seconds
Fahrenheit/Celsius
Error Mode
POSSIBLE CAUSE
Thermistor should be replaced.
Thermistor should be replaced.
Check the card reader wire.
Default
45 Minutes
2 Minutes
154.4° F (68° C)
140° F (60° C)
125.6° F (52.5° C)
15 Minutes
$1.00
$1.00
Minutes
Fahrenheit
On
SOLUTION