6.6.3
Technical specifications
Technical specifications of the PotDis-TB-P1_R terminal block
Article number
General information
Product type designation
Supply voltage
Rated value (DC)
For P1 and P2 bus
•
for process terminals
•
Rated value (AC)
For P1 and P2 bus
•
for process terminals
•
external protection for power supply lines
Current carrying capacity
up to 60 °C, max.
For P1 and P2 bus, max.
For AUX bus, max.
For process terminals, max.
Ambient conditions
Ambient temperature during operation
horizontal installation, min.
•
horizontal installation, max.
•
vertical installation, min.
•
vertical installation, max.
•
Vertical installation, min.
•
Vertical installation, max.
•
Horizontal installation, min.
•
Horizontal installation, max.
•
Altitude during operation relating to sea level
Ambient air temperature-barometric pres-
•
sure-altitude
BaseUnits (6ES7193-6BP.../3RK1908-0AP00...)
Manual, 02/2018, A5E03727049-AJ
6ES7193-6TP00-0TP1
PotDis TB P1-R, PU 1
48 V; max.
48 V; max.
240 V; max.
240 V; max.
Yes; 10 A miniature circuit breaker with type B or
C tripping characteristic for the respective rated
supply voltage
10 A
10 A
10 A
10 A
0 °C; No condensation
60 °C
0 °C; No condensation
50 °C
0 °C; No condensation
50 °C
0 °C; No condensation
50 °C
On request: Ambient temperatures lower than 0
°C (without condensation) and/or installation
altitudes greater than 2 000 m
Potential distributor modules
6.6 PotDis-TB
133