Download Print this page
IKUSI SPI-300 Setup Manual
IKUSI SPI-300 Setup Manual

IKUSI SPI-300 Setup Manual

For mcp modulators
Hide thumbs Also See for SPI-300:

Advertisement

VIDEO
VIDEO
VIDEO
VIDEO
L
L
L
(Mono)
(Mono)
(Mono)
AUDIO
AUDIO
AUDIO
AUDIO
R
R
R
CONTROL
CONTROL
CONTROL
CONTROL
CFP-700
STATUS
STATUS
STATUS
STATUS
POWER
+12V
+12V
+12V
+12V
+12V
5A
+24V
+18V
MCP-411
MCP-400
MCP-411
MCP-411
300 mA
TV MODULATOR
TV MODULATOR
TV MODULATOR
TV MODULATOR
(22 KHz)
TV SYSTEM
+13V
300 mA
(22 KHz)
+18V
300 mA
RF OUT
RF OUT
RF OUT
RF OUT
+13V
300 mA
I
:700 mA
TOT (MAX)
SETUP GUIDE FOR
«MCP» MODULATORS
USING THE SPI-300 PROGRAMMING UNIT
Programming the MCP Modulators
1. THE START SCREENS
1.1 - Module Basic Information
As explained in the Basic Handling guide supplied with the SPI-300, when you
connect this to the module all data for identification, configuration and status of the
module are loaded on the SPI-300. A detection screen appears for a short time, and
next the display shows the Basic Information screen, which identifies the module and
presents its most representative configuration and status data.
The basic information screen for the MCP-400 modulators is the following :
MCP-422
F01.02
Out.Freq.: 687.25
These are the meanings of the expressions and data displayed :
- Name of the module.
- "F-.-" : Version of the firmware (the firmware is the software stored in the module
that manages its basic running).
- "Output Frequency" : Is the video carrier of the output TV channel, in MHz.
- "Alarm" : Informs about the existence or not of module working failures.
- "Audio" : Displays the Audio Mode (mono, stereo, dual) that is selected in the
modulator. System A2.
- "TV System" : Is the TV system (fixed or selected) of the output TV channel.
The screen closes using the OK command (key
appears (page 8 of the Basic Handling guide).
GB
-30 dB
VIDEO
VIDEO
VIDEO
VIDEO
OUTPUT TEST
L
L
L
L
L
(Mono)
(Mono)
(Mono)
(Mono)
(Mono)
AUDIO
AUDIO
AUDIO
AUDIO
OUTPUT
R
R
R
R
R
HPA-120
Ref. 4426
SPI-300
BROADBAND AMPLIFIER
47-862 MHz
CONTROL
CONTROL
CONTROL
CONTROL
GAIN
STATUS
STATUS
STATUS
STATUS
ON
+12V
+12V
+12V
+12V
+12V
1
2
3
EXT INPUT
MCP-400
MCP-400
MCP-411
MCP-411
Gain 6 dB
TV MODULATOR
TV MODULATOR
TV MODULATOR
TV MODULATOR
4
5
6
TV SYSTEM
TV SYSTEM
7
8
9
RF OUT
RF OUT
RF OUT
RF OUT
INPUT
-20 dB
INPUT TEST
C
0
Alarm:No
Audio:Stereo
TVSys:DK
OK
). Then the Main Menu Screen
1. The Start Screens
1.1 - Module Basic Information ...................................................... 3
1.2 - Main Menus .......................................................................... 4
2. The Setting Screens
2.1 - The RF Screen ................................................................. 5 / 6
2.2 - The Video Screen ................................................................ 7
2.3 - The Audio Screen .................................................................. 8
3. The Information Screens
3.1 - The Alarms Screen ................................................................ 9
3.2 - The Details Screen ................................................................ 9
4. The Divers Screens
4.1 - The Configurations Screen ................................................. 10
1
Programming the MCP Modulators
1.2 - Main Menus
As explained in the Basic Handling guide, the General menu is identical for all the
modules and its contents was described on page 8. The Settings and Info menus
include, however, options and information which are peculiar to each type of module.
Those of the MCP modulators are the following:
- Settings Menu : Contains all the setting parameters of the connected modulator,
grouped by sections which are displayed on one or several screens. There are
three sections :
RF : You must select it to set the parameter values related to the RF output
signal of the modulator.
Video : Allows to select the available video options.
Audio : Idem, the audio options.
- Info Menu: Allows to get access to detailled information about the funtionning of
the module, further on the one provided by the basic information screen (see
previous page). Information is distributed in two screens, each one related to a
menu option:
Alarms : Informs whether the module has some alarm activated and its type.
Details : Identifies the module and displays outstanding data.
3
Index
1  RF
2
Video
3
Audio
ESC
SEL
1  Alarms
2
Details
ESC
SEL
2
4

Advertisement

loading
Need help?

Need help?

Do you have a question about the SPI-300 and is the answer not in the manual?

Questions and answers

Summary of Contents for IKUSI SPI-300

  • Page 1 Those of the MCP modulators are the following: module are loaded on the SPI-300. A detection screen appears for a short time, and next the display shows the Basic Information screen, which identifies the module and - Settings Menu : Contains all the setting parameters of the connected modulator, presents its most representative configuration and status data.
  • Page 2 Programming the MCP Modulators Programming the MCP Modulators Press the key ↓ to reach the second page of the RF screen, where you can do the 2. THE SETTING SCREENS following selections : 2.1 - The RF Screen This screen appears when you select the RF option in the Settings Menu. It contains ‘...
  • Page 3 This screen identifies the module and displays outstanding data : MCP-421 F01.02 Use the OK command (key ) to close the screen. IKUSI - Angel Iglesias, S.A. Paseo Miramón, 170 20009 San Sebastián SPAIN Tel.: +34 943 44 88 00 Fax: +34 943 44 88 19 www.ikusi.com...