Honeywell 4AV15F Installation Instructions

4av series vane

Advertisement

Quick Links

Installation Instructions for the
4AV Series Vane Sensors
PERSONAL INJURY
DO NOT USE these products as safety or
emergency stop devices or in any other application
where failure of the product could result in personal
injury.
Failure to comply with these instructions could
result in death or serious injury.
ELECTRICAL CHARACTERISTICS
Catalog
Termination
Listing
4AV15F
24 AWG Wire
4AV16F
24 AWG Wire
4AV17F
24 AWG Wire
4AV18F
24 AWG Wire
4AV19F
24 AWG Wire
4AV20F
.015 X .025 PCB
4AV20F-T1*
.025 X .025
Connector
4AV20F-T2**
.025 X .025
Connector
*Will mate with AMP Connector Housing 87499-8, not supplied
**Will mate with Molex Connector Housing 2695/6471, not supplied
VANE DIMENSIONS (mm/in)
Thickness
Min.
Window
1,0/0.4
10,2/.40
1,6/.06
10,2/.40
MICRO SWITCH Sensing and Control
Supply
Lead
Voltage
Length
All Listings
5.50 ± 0.25
7.45 ± 0.25
4.5 VDC
through
13.15 ± 0.50
26.5 VDC
18.15 ± 0.50
22.00 ± 0.50
0.140
AMP Terminal
Block 103323-4
Molex Terminal
Block 22-05-3041
Min.
Min. Tooth
Tooth
Depth
10,2/.40
9,27/.365
6,3/.25
9,27/.365
GENERAL INFORMATION
4AV Hall effect vane sensors include a Hall effect
sensor and a magnet in a common package. They
are operated by passing a ferrous vane through the
gap between the magnet and the sensor.
With no vane in the gap, the output is Operated
(conducting). With the vane in the gap, the output is
Released (non-conducting). The vane actuator is
annealed low carbon cold rolled steel, type AISI
1018 or lower in carbon. Minimum recommended
vane dimensions are required to ensure operating
characteristics will be met.
Supply
Output
Current
Voltage
All Listings
All listings
18.5 mA Max
0.4 V Max
@ -40 °C
@125 °C
15.25 mA typical
0.1 typical
11.75 mA
0.075 V
@25 °C
@25 °C typical
typical
ISSUE 2
PK 87605
Output
Sink Current
All listings
40 mA Max
Dual output
sink currents
are summed
to reach total.

Advertisement

loading

Summary of Contents for Honeywell 4AV15F

  • Page 1 Voltage Sink Current Listing Length All Listings All Listings All listings All listings 5.50 ± 0.25 4AV15F 24 AWG Wire 18.5 mA Max 0.4 V Max @ -40 °C @125 °C 7.45 ± 0.25 4.5 VDC 40 mA Max 4AV16F...
  • Page 2 • Do not reverse supply voltage polarity. • Handle terminals with care. Failure to comply with these instructions may result in product damage. Mates with AMP housing 87499-8 2 Honeywell • MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945...
  • Page 3 • Ensure cleaner does not come in contact with sensor If other cleaning methods are selected for removal of flux residue. Failure to comply with these instructions may result in product damage. Honeywell • MICRO SWITCH Sensing and Control 3 For application help: call 1-800-537-6945...
  • Page 4 If warranted goods are For application assistance, current specifications, returned to Honeywell during the period of coverage, or name of the nearest Authorized Distributor, Honeywell will repair or replace without charge those contact a nearby sales office.