Page 1
0102 095 50023 CLASS 2 – FLAME SYSTEM 3 USERS / INSTALLATION (Pages 2-3) (Pages 4-9) AND SERVICING INSTRUCTIONS THIS CAT I APPLIANCE IS FOR USE ON NATURAL GAS G20 AT A SUPPLY PRESSURE OF 20 mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER...
Description This Royal Cozy Fires Decorative Fuel Effect gas fire has been developed to give a realistic coal burning appearance with the instant control and convenience of gas. The fire has been constructed to enable it to be installed into most applications (using the optional spacer frame) where the warmth and comfort of an open fire with high radiant heat is required.
Page 3
3. 0nce a pilot-flame has been established; keep the control depressed for a further 20 seconds. Release the gas control and check that the pilot remains lit. 4. Depress the gas control slightly and turn anti-clockwise until the indicator mark is aligned with the letters HIGH. The burner will cross light from the pilot.
THE FOLLOWING SECTION LISTS THE INSTALLATION REQUIREMENTS AND REGULATIONS A competent person in accordance with the current Gas Safety (Installation and Use) Regulations or the rules in force and in accordance with the manufacturer’s instructions must install the appliance; failure to do so could lead to prosecution. The following are the relevant Codes of Practice and British Standards.
Page 5
Installing the Appliance Check that the chimney and flue structure are sound and conform to the following flue requirements. a) A conventional brick or stone chimney with a minimum effective cross sectional dimension of 225 x 225mm. A lined flue with a minimum diameter of 175mm having a chairbrick and throat forming lintel conforming to BS 1251 or a builders opening (constructed of non-combustible material) measuring 540mm high x 400mm wide with a sufficient depth for debris collection.
Installation using a 5” Diameter Metal Flue Box Important: The spigot restrictor marked ’B’ must be fitted. See page 7. When the metal flue box is to be built-in as a false chimneybreast using the timber studwork with plasterboard facing, the metal flue box should be enveloped with insulation material such as Rockwool or similar to prevent a build-up of heat within the structure.
Page 7
The two slots in the rear of the base of the firebox may be used to secure the appliance in position. Where no spacer is used the unit will require securing at the top using the two holes in the top corner plate and the No 10 c/sk screws provided.
Page 8
Checking Operation of Fire Turn on the gas supply at the meter and to the appliance at the isolating cock. Purge the air from the appliance. Press and turn the gas control anti-clockwise, keep the control fully depressed. The igniter will operate and the pilot will light, check that the electrode is sparking to the head of the pilot burner, continue until a pilot ignition is established.
Page 9
0102 078 00061 0102 078 00021 0102 078 00041 0102 078 00401 0102 078 00271 0102 092 40021 Royal Cozyfires are manufactured by: CROSSLEE plc Aber Park Industrial Estate, Aber Road, Flint, Flintshire. CH6 5EX Spares Tel 01422 203963 Fax: 01422 204475...
Page 11
Depth A is to be a minimum of 150mm from the knee to the front face of the surround with the sapcer fitted to satisfy the debris collection requirement Depth B is Nominally 70mm. If no chairbrick is fitted, the minimum distance required between the rear of the opening and the front face of the surround is 210mm without spacer frame fitted.