Cisco Ata 191 And Ata 192 Analog Telephone Adapter Administration Guide For Multiplatform Firmware - Cisco ATA 191 Administration Manual

Analog telephone adapter guide for multiplatform firmware
Hide thumbs Also See for ATA 191:
Table of Contents

Advertisement

Configuration Profile
Field
Resync Periodic:
Resync Error Retry Delay:
Forced Resync Delay:
Resync From SIP:
Resync After Upgrade Attempt:
Resync Trigger 1:
Resync Trigger 2:

Cisco ATA 191 and ATA 192 Analog Telephone Adapter Administration Guide for Multiplatform Firmware

50
Voice Settings Configuration
Description
The time interval between periodic resyncs with the
provisioning server. The associated resync timer is
active only after the first successful synchronization
with the server. Setting this parameter to zero disables
periodic resynchronization.
Default setting: 3600
Resync retry interval (in seconds) applied if there is
a resync failure. The ATA has an error retry timer
that activates if the previous attempt to sync with the
provisioning server fails. The ATA waits to contact
the server again until the timer counts down to zero.
This parameter is the value that is initially loaded into
the error retry timer. If this parameter is set to zero,
the ATA immediately retries to sync with the
provisioning server following a failed attempt.
Default setting: 3600
Maximum delay (in seconds) that the ATA waits
before performing a resync. The ATA does not resync
while one of its lines is active. Because a resync can
take several seconds, it is desirable to wait until the
ATA has been idle for an extended period before
resynchronizing. It allows you to make calls in
succession without interruption.
The ATA has a timer that begins counting down when
all lines become idle. This parameter is the initial
value of the counter.
Resync events are delayed until this counter
decrements to zero.
Default setting: 14400
Enables a resync to be triggered with a SIP NOTIFY
message.
Default setting: yes
Triggers a resync after every firmware upgrade
attempt.
Default setting: yes
Configurable resync trigger conditions. A resync is
triggered when the logic equation in these parameters
evaluates to TRUE.
Default setting: blank

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ata 192