Mitsubishi Electric AJ65SBT2B-64AD User Manual page 23

Analog-digital converter module
Table of Contents

Advertisement

No.
Name
With the STATION NO. "10", "20", and "40" switches, the tens place of the
station number is set.
With the STATION NO. "1", "2", "4", and "8" switches, the ones place of the
station number is set.
These switches are all set to off at default.
A station number must be set within 1 to 64.
Setting any number other than that will result in an error, and the L ERR.
LED will turn on.
The same station number cannot be set to several stations.
Station
number
4
setting
switch
(Example) To specify "32" for a station number, set the switches as shown
below.
Use
All switches must be set to off.
5
prohibited
A terminal block for transmission and module power supply lines
Terminal
block for
transmission
6
and module
power supply
lines
Table 3.1 Part names
Tens place
Station
number
40
1
OFF
OFF
2
OFF
OFF
3
OFF
OFF
4
OFF
OFF
10
OFF
OFF
11
OFF
OFF
64
ON
Tens place
Station
number
40
1
OFF
Terminal
DA
DB
DG
SLD
FG
+24V
Terminals for connecting an external power supply
24G
Description
20
10
8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
20
10
8
ON
ON
OFF
Description
Terminals for connecting CC-Link dedicated
A terminal for grounding to the protective ground
conductor
8
Ones place
4
2
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
Ones place
4
2
OFF
ON
cables
1
ON
OFF
ON
OFF
OFF
ON
OFF
1
OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents